Back to Search
Start Over
Comparison of pressure, temperature and specific humidity from COSMIC-2 with radiosonde and ERA5.
- Source :
- Journal of Spatial Science; May2024, Vol. 69 Issue 2, p507-525, 19p
- Publication Year :
- 2024
-
Abstract
- Pressure, temperature and specific humidity profiles from COSMIC-2 are compared with those from ERA5 and radiosonde data from October 2019 to September 2020. The results demonstrate that COSMIC-2 pressure and specific humidity profiles show relatively poor accuracy and stability in the lower troposphere. The 1D-Var solution effectively improves the accuracy of temperature parameters in the troposphere. Three parameters show high accuracy over one climatological year, but show slight seasonal fluctuations, especially for the specific humidity profiles in summer. Furthermore, COSMIC-2 specific humidity data show low consistency with radiosonde and ERA5 in the equatorial region. [ABSTRACT FROM AUTHOR]