Back to Search Start Over

Energy Loss Index and Dimensionless Index Outperform Direct Valve Planimetry in Low-Gradient Aortic Stenosis.

Authors :
Hugelshofer, Sarah
de Brito, Diana
Antiochos, Panagiotis
Tzimas, Georgios
Rotzinger, David C.
Auberson, Denise
Vella, Agnese
Fournier, Stephane
Kirsch, Matthias
Muller, Olivier
Monney, Pierre
Source :
Journal of Clinical Medicine; Jun2024, Vol. 13 Issue 11, p3220, 11p
Publication Year :
2024

Abstract

Background/Objectives: Among patients with suspected severe aortic stenosis (AS), discordance between effective orifice area (EOA) and transvalvular gradients is frequent and requires a multiparametric workup including flow assessment and calcium-scoring to confirm true severe AS. The aim of this study was to assess direct planimetry, energy loss index (Eli) and dimensionless index (DI) as stand-alone parameters to identify non-severe AS in discordant cases. Methods: In this prospective cohort study, we included consecutive AS patients > 70 years with EOA < 1.0 cm<superscript>2</superscript> referred for valve replacement between 2014 and 2017. AS severity was retrospectively reassessed using the multiparametric work-up recommended in the 2021 ESC/EACTS guidelines. DI and ELi were calculated, and valve area was measured by direct planimetry on transesophageal echocardiography. Results: A total of 101 patients (mean age 82 y; 57% male) were included. Discordance between EOA and gradients was observed in 46% and non-severe AS found in 24% despite an EOA < 1 cm<superscript>2</superscript>. Valve planimetry performed poorly, with an area under the ROC curve (AUC) of 0.64. At a cut-off value of >0.82 cm<superscript>2</superscript>, sensitivity and specificity to identify non-severe AS were 67 and 66%, respectively. DI and ELi showed a higher diagnostic accuracy, with an AUC of 0.77 and 0.76, respectively. Cut-off values of >0.24 and >0.6 cm<superscript>2</superscript>/m<superscript>2</superscript> identified non-severe AS, with a high specificity of 79% and 91%, respectively. Conclusions: Almost one in four patients with EOA < 1 cm<superscript>2</superscript> had non-severe AS according to guideline-recommended multiparametric assessment. Direct valve planimetry revealed poor diagnostic accuracy and should be interpreted with caution. Usual prognostic cut-off values for DI > 0.24 and ELI > 0.6 cm<superscript>2</superscript>/m<superscript>2</superscript> identified non-severe AS with high specificity and should therefore be included in the assessment of low-gradient AS. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20770383
Volume :
13
Issue :
11
Database :
Complementary Index
Journal :
Journal of Clinical Medicine
Publication Type :
Academic Journal
Accession number :
177872461
Full Text :
https://doi.org/10.3390/jcm13113220