Back to Search
Start Over
Prediction of Lymph Node Metastasis in T1 Colorectal Cancer Using Artificial Intelligence with Hematoxylin and Eosin-Stained Whole-Slide-Images of Endoscopic and Surgical Resection Specimens.
- Source :
- Cancers; May2024, Vol. 16 Issue 10, p1900, 16p
- Publication Year :
- 2024
-
Abstract
- Simple Summary: We developed an attention-based whole slide image (WSI)-level classification deep learning model employing surgically and endoscopically resected specimens to predict LNM in T1 CRC. Our AI model with H&E-stained WSIs and without annotations showed good performance power with the validation of an independent cohort in a single center. The area under the curve of our model was 0.781–0.824, higher than that of previous artificial intelligence (AI) studies with only WSIs. Our AI model, which showed the highest sensitivity (92.9%), reduced unnecessary additional surgery by 14.2% more than using the current JSCCR guidelines (68.3% vs. 82.5%). This revealed the feasibility of using an AI model with only H&E-stained WSIs to predict LNM in T1 CRC. According to the current guidelines, additional surgery is performed for endoscopically resected specimens of early colorectal cancer (CRC) with a high risk of lymph node metastasis (LNM). However, the rate of LNM is 2.1–25.0% in cases treated endoscopically followed by surgery, indicating a high rate of unnecessary surgeries. Therefore, this study aimed to develop an artificial intelligence (AI) model using H&E-stained whole slide images (WSIs) without handcrafted features employing surgically and endoscopically resected specimens to predict LNM in T1 CRC. To validate with an independent cohort, we developed a model with four versions comprising various combinations of training and test sets using H&E-stained WSIs from endoscopically (400 patients) and surgically resected specimens (881 patients): Version 1, Train and Test: surgical specimens; Version 2, Train and Test: endoscopic and surgically resected specimens; Version 3, Train: endoscopic and surgical specimens and Test: surgical specimens; Version 4, Train: endoscopic and surgical specimens and Test: endoscopic specimens. The area under the curve (AUC) of the receiver operating characteristic curve was used to determine the accuracy of the AI model for predicting LNM with a 5-fold cross-validation in the training set. Our AI model with H&E-stained WSIs and without annotations showed good performance power with the validation of an independent cohort in a single center. The AUC of our model was 0.758–0.830 in the training set and 0.781–0.824 in the test set, higher than that of previous AI studies with only WSI. Moreover, the AI model with Version 4, which showed the highest sensitivity (92.9%), reduced unnecessary additional surgery by 14.2% more than using the current guidelines (68.3% vs. 82.5%). This revealed the feasibility of using an AI model with only H&E-stained WSIs to predict LNM in T1 CRC. [ABSTRACT FROM AUTHOR]
- Subjects :
- LYMPH nodes
RISK assessment
PREDICTION models
T-test (Statistics)
RECEIVER operating characteristic curves
DATA analysis
STATISTICAL significance
RESEARCH funding
ARTIFICIAL intelligence
COLORECTAL cancer
ENDOSCOPIC surgery
MINIMALLY invasive procedures
MANN Whitney U Test
DESCRIPTIVE statistics
METASTASIS
DEEP learning
DATA analysis software
ENDOSCOPY
DISEASE complications
Subjects
Details
- Language :
- English
- ISSN :
- 20726694
- Volume :
- 16
- Issue :
- 10
- Database :
- Complementary Index
- Journal :
- Cancers
- Publication Type :
- Academic Journal
- Accession number :
- 177490668
- Full Text :
- https://doi.org/10.3390/cancers16101900