Prediction of Lymph Node Metastasis in T1 Colorectal Cancer Using Artificial Intelligence with Hematoxylin and Eosin-Stained Whole-Slide-Images of Endoscopic and Surgical Resection Specimens.

Authors :
Song, Joo Hye
Kim, Eun Ran
Hong, Yiyu
Sohn, Insuk
Ahn, Soomin
Kim, Seok-Hyung
Jang, Kee-Taek
Source :
Cancers; May2024, Vol. 16 Issue 10, p1900, 16p
Publication Year :
2024

Abstract

Simple Summary: We developed an attention-based whole slide image (WSI)-level classification deep learning model employing surgically and endoscopically resected specimens to predict LNM in T1 CRC. Our AI model with H&E-stained WSIs and without annotations showed good performance power with the validation of an independent cohort in a single center. The area under the curve of our model was 0.781–0.824, higher than that of previous artificial intelligence (AI) studies with only WSIs. Our AI model, which showed the highest sensitivity (92.9%), reduced unnecessary additional surgery by 14.2% more than using the current JSCCR guidelines (68.3% vs. 82.5%). This revealed the feasibility of using an AI model with only H&E-stained WSIs to predict LNM in T1 CRC. According to the current guidelines, additional surgery is performed for endoscopically resected specimens of early colorectal cancer (CRC) with a high risk of lymph node metastasis (LNM). However, the rate of LNM is 2.1–25.0% in cases treated endoscopically followed by surgery, indicating a high rate of unnecessary surgeries. Therefore, this study aimed to develop an artificial intelligence (AI) model using H&E-stained whole slide images (WSIs) without handcrafted features employing surgically and endoscopically resected specimens to predict LNM in T1 CRC. To validate with an independent cohort, we developed a model with four versions comprising various combinations of training and test sets using H&E-stained WSIs from endoscopically (400 patients) and surgically resected specimens (881 patients): Version 1, Train and Test: surgical specimens; Version 2, Train and Test: endoscopic and surgically resected specimens; Version 3, Train: endoscopic and surgical specimens and Test: surgical specimens; Version 4, Train: endoscopic and surgical specimens and Test: endoscopic specimens. The area under the curve (AUC) of the receiver operating characteristic curve was used to determine the accuracy of the AI model for predicting LNM with a 5-fold cross-validation in the training set. Our AI model with H&E-stained WSIs and without annotations showed good performance power with the validation of an independent cohort in a single center. The AUC of our model was 0.758–0.830 in the training set and 0.781–0.824 in the test set, higher than that of previous AI studies with only WSI. Moreover, the AI model with Version 4, which showed the highest sensitivity (92.9%), reduced unnecessary additional surgery by 14.2% more than using the current guidelines (68.3% vs. 82.5%). This revealed the feasibility of using an AI model with only H&E-stained WSIs to predict LNM in T1 CRC. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20726694
Volume :
16
Issue :
10
Database :
Complementary Index
Journal :
Cancers
Publication Type :
Academic Journal
Accession number :
177490668
Full Text :
https://doi.org/10.3390/cancers16101900