Back to Search Start Over

Rapid Environmental Contamination With Candida auris and Multidrug-Resistant Bacterial Pathogens Near Colonized Patients.

Authors :
Sansom, Sarah E
Gussin, Gabrielle M
Schoeny, Michael
Singh, Raveena D
Adil, Hira
Bell, Pamela
Benson, Ellen C
Bittencourt, Cassiana E
Black, Stephanie
Guzman, Maria Del Mar Villanueva
Froilan, Mary Carl
Fukuda, Christine
Barsegyan, Karina
Gough, Ellen
Lyman, Meghan
Makhija, Jinal
Marron, Stefania
Mikhail, Lydia
Noble-Wang, Judith
Pacilli, Massimo
Source :
Clinical Infectious Diseases; 5/15/2024, Vol. 78 Issue 5, p1276-1284, 9p
Publication Year :
2024

Abstract

Background Environmental contamination is suspected to play an important role in Candida auris transmission. Understanding speed and risks of contamination after room disinfection could inform environmental cleaning recommendations. Methods We conducted a prospective multicenter study of environmental contamination associated with C. auris colonization at 6 ventilator-capable skilled nursing facilities and 1 acute care hospital in Illinois and California. Known C. auris carriers were sampled at 5 body sites followed by sampling of nearby room surfaces before disinfection and at 0, 4, 8, and 12 hours after disinfection. Samples were cultured for C. auris and bacterial multidrug-resistant organisms (MDROs). Odds of surface contamination after disinfection were analyzed using multilevel generalized estimating equations. Results Among 41 known C. auris carriers, colonization was detected most frequently on palms/fingertips (76%) and nares (71%). C. auris contamination was detected on 32.2% (66/205) of room surfaces before disinfection and 20.5% (39/190) of room surfaces by 4 hours after disinfection. A higher number of C. auris –colonized body sites was associated with higher odds of environmental contamination at every time point following disinfection, adjusting for facility of residence. In the rooms of 38 (93%) C. auris carriers co-colonized with a bacterial MDRO, 2%–24% of surfaces were additionally contaminated with the same MDRO by 4 hours after disinfection. Conclusions C. auris can contaminate the healthcare environment rapidly after disinfection, highlighting the challenges associated with environmental disinfection. Future research should investigate long-acting disinfectants, antimicrobial surfaces, and more effective patient skin antisepsis to reduce the environmental reservoir of C. auris and bacterial MDROs in healthcare settings. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10584838
Volume :
78
Issue :
5
Database :
Complementary Index
Journal :
Clinical Infectious Diseases
Publication Type :
Academic Journal
Accession number :
177249807
Full Text :
https://doi.org/10.1093/cid/ciad752