Back to Search Start Over

Characterization and Application of Membrane-emulsified HLB Microspheres for Quantification of 25-Hydroxy Vitamin D2 and 25-Hydroxy Vitamin D3 in Serum by UPLC-MS/MS.

Authors :
Zhang, Jihua
Gong, Zishan
Tie, Hang
Wang, Yanchun
Wang, Xuan
Zhai, Weixiang
Guo, Qiaoyun
Wu, Wenhui
Liu, Jiyang
Xu, Liang
Jing, Wenli
Zhang, Shuo
Source :
Chromatographia; May2024, Vol. 87 Issue 5, p351-361, 11p
Publication Year :
2024

Abstract

Membrane emulsification can obtain microspheres with relatively uniform particle size and pore size, which has unique advantages in the synthesis of polymer microsphere adsorbents and the enrichment and separation of organic compounds. In this study, the Hydrophilic Lipophilic Balance (HLB) solid phase extraction microspheres were prepared by membrane emulsification technique and was used in the pretreatment of samples to detect 25-hydroxy vitamin D<subscript>2</subscript> (25OH-VD<subscript>2</subscript>) and 25-hydroxy vitamin D<subscript>3</subscript> (25OH-VD<subscript>3</subscript>) in serum by UPLC-MS/MS for the first time. To confirm the efficacy of membrane-emulsified (ME) HLB microspheres, three types of microspheres, including ME HLB microspheres, non-membrane-emulsified (non-ME) HLB microspheres and commercial HLB microspheres, were compared for the pretreatment of 25OH-VD<subscript>2</subscript> and 25OH-VD<subscript>3</subscript>. The performance of HLB microspheres was characterized based on the sample recovery values acquired by UPLC-MS/MS analysis. Results showed that among the three types of microspheres, ME HLB microspheres showed the best performance and demonstrated good adsorption properties for 25OH-VD<subscript>2</subscript> and 25OH-VD<subscript>3</subscript>. The recoveries range of 25OH-VD<subscript>2</subscript> and 25OH-VD<subscript>3</subscript> were 96.7–101.4 and 98.7–104.9%, respectively, and the coefficients of variation were 0.67–1.24 and 1.39–2.28%, respectively, which were superior to those of commercial HLB microspheres and non-ME HLB microspheres. Additionally, due to their excellent homogeneity, the ME HLB microspheres exhibited good precision in the determination of low values of 25OH-VD<subscript>2</subscript> and 25OH-VD<subscript>3</subscript>, indicating accurate and simple detection of 25OH-VD<subscript>2</subscript> and 25OH-VD<subscript>3</subscript> with a broad potential for further development. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00095893
Volume :
87
Issue :
5
Database :
Complementary Index
Journal :
Chromatographia
Publication Type :
Academic Journal
Accession number :
177003609
Full Text :
https://doi.org/10.1007/s10337-024-04331-1