Back to Search Start Over

Advancing 6-bromo-7-[11C]methylpurine to clinical use: improved regioselective radiosynthesis, non-clinical toxicity data and human dosimetry estimates.

Authors :
Mairinger, Severin
Jackwerth, Matthias
Soukup, Ondřej
Blaickner, Matthias
Decristoforo, Clemens
Nics, Lukas
Pahnke, Jens
Hacker, Marcus
Zeitlinger, Markus
Langer, Oliver
Source :
EJNMMI Radiopharmacy & Chemistry; 4/29/2024, Vol. 9 Issue 1, p1-13, 13p
Publication Year :
2024

Abstract

Background: 6-Bromo-7-[<superscript>11</superscript>C]methylpurine ([<superscript>11</superscript>C]BMP) is a radiotracer for positron emission tomography (PET) to measure multidrug resistance-associated protein 1 (MRP1) transport activity in different tissues. Previously reported radiosyntheses of [<superscript>11</superscript>C]BMP afforded a mixture of 7- and 9-[<superscript>11</superscript>C]methyl regioisomers. To prepare for clinical use, we here report an improved regioselective radiosynthesis of [<superscript>11</superscript>C]BMP, the results of a non-clinical toxicity study as well as human dosimetry estimates based on mouse PET data. Results: [<superscript>11</superscript>C]BMP was synthesised by regioselective N<superscript>7</superscript>-methylation of 6-bromo-7H-purine (prepared under good manufacturing practice) with [<superscript>11</superscript>C]methyl triflate in presence of 2,2,6,6-tetramethylpiperidine magnesium chloride in a TRACERlab™ FX2 C synthesis module. [<superscript>11</superscript>C]BMP was obtained within a total synthesis time of approximately 43 min in a decay-corrected radiochemical yield of 20.5 ± 5.2%, based on starting [<superscript>11</superscript>C]methyl iodide, with a radiochemical purity > 99% and a molar activity at end of synthesis of 197 ± 130 GBq/μmol (n = 28). An extended single-dose toxicity study conducted in male and female Wistar rats under good laboratory practice after single intravenous (i.v.) administration of unlabelled BMP (2 mg/kg body weight) revealed no test item related adverse effects. Human dosimetry estimates, based on dynamic whole-body PET data in female C57BL/6J mice, suggested that an i.v. injected activity amount of 400 MBq of [<superscript>11</superscript>C]BMP will deliver an effective dose in the typical range of <superscript>11</superscript>C-labelled radiotracers. Conclusions: [<superscript>11</superscript>C]BMP can be produced in sufficient amounts and acceptable quality for clinical use. Data from the non-clinical safety evaluation showed no adverse effects and suggested that the administration of [<superscript>11</superscript>C]BMP will be safe and well tolerated in humans. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
2365421X
Volume :
9
Issue :
1
Database :
Complementary Index
Journal :
EJNMMI Radiopharmacy & Chemistry
Publication Type :
Academic Journal
Accession number :
176995891
Full Text :
https://doi.org/10.1186/s41181-024-00265-z