Development of a LAMP-Based Diagnostic for the Detection of Multiple HIV-1 Strains.

Authors :
Makler-Disatham, Amy
Caputi, Massimo
Asghar, Waseem
Source :
Biosensors (2079-6374); Apr2024, Vol. 14 Issue 4, p157, 10p
Publication Year :
2024

Abstract

Since its first appearance in 1981, HIV-1 has remained a global concern. Current methods for diagnosing HIV-1, while effective, are mostly specific to a given subtype of HIV-1 and often require expensive equipment and highly trained individuals to collect and process the sample. It is necessary to develop a sensitive diagnostic method that can be administered with minimal equipment to provide better care in low-resource settings. Loop-mediated isothermal amplification is a rapid and sensitive method for detecting the presence of specific nucleic acid sequences. Herein we report the development and comparison of two different HIV LAMP assays, integrase and VPR, as well as the comparison between TRIZol and magnetic beads RNA extraction methods for each assay. Our analysis shows that the integrase assay was able to detect the virus from multiple subtypes in under 30 min with a variable limit of detection (LOD) that was dependent on the HIV-1 subtype. [ABSTRACT FROM AUTHOR]