Back to Search Start Over

Performance assessment of up-flow anaerobic multi-staged reactor followed by auto-aerated immobilized biomass unit for treating polyester wastewater, with biogas production.

Authors :
Hassan, Raouf
Kriaa, Karim
Wahaballa, Amr M.
Elsayed, Mahmoud
Mahmoud, M.
Nasr, Mahmoud
Tawfik, Ahmed
Source :
Applied Water Science; Apr2024, Vol. 14 Issue 4, p1-16, 16p
Publication Year :
2024

Abstract

Polyester manufacturing industries produce highly polluted effluents, containing organics, nutrients, trace metals, and 1,4-dioxane, requiring a high degree of treatment before being discharged into the water bodies. This study focused on removing complex pollutants from a diluted polyester industrial effluent (DPIE) via a cost-efficient anaerobic/aerobic combined system, with biogas recovery. The integrated pilot-scale system was composed of an up-flow anaerobic multi-staged reactor (UASR; V = 41 L) followed by an auto-aerated immobilized biomass (AIB; V<subscript>sponge</subscript> = 9.54 L) unit and operated at a total organic loading rate (OLR) of 0.75 ± 0.16 g COD/L/d and pH of 7.14 ± 0.14 at 25 °C. The UASR achieved removal efficiencies of 17.82 ± 3.14% and 15.90 ± 3.08% for chemical oxygen demand (COD, total and soluble) and 15.83 ± 4.68% for total Kjeldahl nitrogen (TKN), with bio-CH<subscript>4</subscript> yield of 263.24 ± 31.98 mL/g COD. Adding the AIB unit improved the overall COD<subscript>total</subscript>, COD<subscript>soluble</subscript>, and TKN to 93.94 ± 2.39%, 94.84 ± 2.23%, and 75.81 ± 3.66%, respectively. The NH<subscript>4</subscript>-N removal efficiency was 85.66 ± 2.90% due to the oxic/nitrification condition on the sponge's outer surface. The entire system also achieved 73.26 ± 2.68%, 77.48 ± 5.74%, and 81.26 ± 6.17% removals for Fe (3.93 ± 0.95 ppm), Zn (5.92 ± 2.32 ppm), and 1,4 dioxane (2.50 ± 0.61 ppm). Moreover, the UASR-AIB maintained removal efficiencies of 76.53 ± 8.47% and 77.51 ± 7.38% for total suspended solids (TSS: 335.95 ± 42.84 mg/L) and volatile suspended solids (VSS: 263.50 ± 36.94 mg/L). Regarding the DPIE toxicity level, the EC<subscript>50</subscript> value increased from 12.9 to 39.4% after UASR/AIB application. The UASR's microbial community at the genus level demonstrated that the synergistic cooperation of solubilization, hydrolysis, acidogenesis, acetogenesis, and methanogenesis was responsible for the degradation of DPIE components. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
21905487
Volume :
14
Issue :
4
Database :
Complementary Index
Journal :
Applied Water Science
Publication Type :
Academic Journal
Accession number :
176652681
Full Text :
https://doi.org/10.1007/s13201-024-02129-y