High-power short-duration catheter ablation of atrial fibrillation: is it really a new era? Comparison between new and old radiofrequency contact force–sensing catheters.

Authors :
Dello Russo, Antonio
D'Angelo, Leonardo
Compagnucci, Paolo
Cipolletta, Laura
Parisi, Quintino
Valeri, Yari
Campanelli, Francesca
Volpato, Giovanni
Carboni, Laura
Ciliberti, Giuseppe
Stronati, Giulia Emily
Barbarossa, Alessandro
La Piscopia, Valentina
Bondavalli, Barbara
Guerra, Federico
Natale, Andrea
Casella, Michela
Source :
Journal of Interventional Cardiac Electrophysiology; Apr2024, Vol. 67 Issue 3, p549-557, 9p
Publication Year :
2024

Abstract

Background: The clinical performance of high-power, short-duration (HPSD) pulmonary vein isolation (PVI) with the novel flexible tip TactiFlex™ (TFSE) catheter, as compared to standard-power, long-duration (SPLD) PVI using the TactiCath™ (TCSE) catheter among patients undergoing catheter ablation (CA) of atrial fibrillation (AF) is currently unknown. Methods: We conducted a prospective, observational, single-centre study including 40 consecutive patients undergoing PVI for paroxysmal/persistent AF, using HPSD ablation with the novel TFSE catheter (HPSD/TFSE group). Based on propensity score-matching, forty patients undergoing SPLD PVI with the TCSE catheter were identified (SPLD/TCSE group). In the HPSD/TFSE group, RF lesions were performed by delivering 40–50 W for 10–20 s, while in the SPLD/TCSE group, RF power was 30–35 W, targeting a lesion size index (LSI) of 4.0–5.5. The co-primary study outcomes were time required to complete PVI and first pass isolation (FPI). Results: PVI was achieved in 100% of patients in both groups, and no major adverse events were observed. Remarkably, PVI time was shorter in the HPSD/TFSE, compared to the SPLD/TCSE group(9 [7–9] min vs. 50 [37–54] min; p < 0.001), while FPI rate was non-significantly higher in the former group(91% [146/160] vs 83% [134/160]; p = 0.063). Shorter procedural (108 [91–120] min vs. 173 [139–187] min, p < 0.001), total RF (9 [7–11] min vs. 43 [32–53] min, p < 0.001), fluoroscopy times(15 [10–19] min vs. 18 [13–26] min, p = 0.014), and lower DAP (1461 [860–2181] vs. 7200 [3400–20,800], p < 0.001) were recorded in the HPSD/TFSE group. A higher average impedance drop was obtained with HPSD/TFSE CA(17[17–18]Ω vs. 16 [15–17] Ω, p < 0.001). Conclusions: In our initial clinical experience, HPSD PVI with the TFSE catheter proved faster than SPLD PVI with the TCSE catheter, at least equally effective in terms of FPI, and it was associated with greater impedance drop. Main study findings. Abbreviations: DAP, dose area product; HPSD–TFSE, high-power short-duration with the TactiFlex™, Sensor Enabled™ catheter; PVI, pulmonary vein isolation; RF, radiofrequency energy; SPLD–TCSE, standard-power long-duration ablation with the TactiCath, Sensor Enabled™ catheter [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1383875X
Volume :
67
Issue :
3
Database :
Complementary Index
Journal :
Journal of Interventional Cardiac Electrophysiology
Publication Type :
Academic Journal
Accession number :
176584573
Full Text :
https://doi.org/10.1007/s10840-023-01612-x