Back to Search Start Over

EFFECT OF PARTICLE DIAMETER SIZE ON INTERNAL FLOW CHARACTERISTICS OF A SMALL SEWAGE PUMP.

Authors :
Yu-Liang Zhang
Dong-Yang Wu
Hai-Bing Cai
Can-Fei Wang
Fei-Wu
Shao-Han Zheng
Source :
Frontiers in Heat & Mass Transfer; 2023, Vol. 20, p1-5, 5p
Publication Year :
2023

Abstract

In this paper, based on the Mixture model, the numerical computations of the internal flow field in a sewage pump are carried out. Through numerical simulation, the turbulence flow characteristics in the sewage pump are obtained. Results show that when the particle diameter is 0.10 mm, the solid-phase concentration on the volute surface is high, and the wear is more severe. When the particle diameters are 0.15 mm and 0.20 mm, the solid-phase concentration on the volute surface is significantly higher, especially when the over-current cross-section enlarges constantly. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
21518629
Volume :
20
Database :
Complementary Index
Journal :
Frontiers in Heat & Mass Transfer
Publication Type :
Academic Journal
Accession number :
176260469
Full Text :
https://doi.org/10.5098/hmt.20.11