Back to Search Start Over

The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge.

Authors :
Shalom, Eve S.
Kim, Harrison
van der Heijden, Rianne A.
Ahmed, Zaki
Patel, Reyna
Hormuth, David A.
DiCarlo, Julie C.
Yankeelov, Thomas E.
Sisco, Nicholas J.
Dortch, Richard D.
Stokes, Ashley M.
Inglese, Marianna
Grech‐Sollars, Matthew
Toschi, Nicola
Sahoo, Prativa
Singh, Anup
Verma, Sanjay K.
Rathore, Divya K.
Kazerouni, Anum S.
Partridge, Savannah C.
Source :
Magnetic Resonance in Medicine; May2024, Vol. 91 Issue 5, p1803-1821, 19p
Publication Year :
2024

Abstract

Purpose: Ktrans$$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for Ktrans$$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize Ktrans$$ {K}^{\mathrm{trans}} $$ measurement. Methods: A framework was created to evaluate Ktrans$$ {K}^{\mathrm{trans}} $$ values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for Ktrans$$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' Ktrans$$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIPIgold$$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. Results: Across the 10 received submissions, the OSIPIgold$$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in Ktrans$$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. Conclusions: This study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within Ktrans$$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07403194
Volume :
91
Issue :
5
Database :
Complementary Index
Journal :
Magnetic Resonance in Medicine
Publication Type :
Academic Journal
Accession number :
176118890
Full Text :
https://doi.org/10.1002/mrm.29909