Back to Search
Start Over
Self‐applied somnography: technical feasibility of electroencephalography and electro‐oculography signal characteristics in sleep staging of suspected sleep‐disordered adults.
- Source :
- Journal of Sleep Research; Apr2024, Vol. 33 Issue 2, p1-13, 13p
- Publication Year :
- 2024
-
Abstract
- Summary: Sleep recordings are increasingly being conducted in patients' homes where patients apply the sensors themselves according to instructions. However, certain sensor types such as cup electrodes used in conventional polysomnography are unfeasible for self‐application. To overcome this, self‐applied forehead montages with electroencephalography and electro‐oculography sensors have been developed. We evaluated the technical feasibility of a self‐applied electrode set from Nox Medical (Reykjavik, Iceland) through home sleep recordings of healthy and suspected sleep‐disordered adults (n = 174) in the context of sleep staging. Subjects slept with a double setup of conventional type II polysomnography sensors and self‐applied forehead sensors. We found that the self‐applied electroencephalography and electro‐oculography electrodes had acceptable impedance levels but were more prone to losing proper skin–electrode contact than the conventional cup electrodes. Moreover, the forehead electroencephalography signals recorded using the self‐applied electrodes expressed lower amplitudes (difference 25.3%–43.9%, p < 0.001) and less absolute power (at 1–40 Hz, p < 0.001) than the polysomnography electroencephalography signals in all sleep stages. However, the signals recorded with the self‐applied electroencephalography electrodes expressed more relative power (p < 0.001) at very low frequencies (0.3–1.0 Hz) in all sleep stages. The electro‐oculography signals recorded with the self‐applied electrodes expressed comparable characteristics with standard electro‐oculography. In conclusion, the results support the technical feasibility of the self‐applied electroencephalography and electro‐oculography for sleep staging in home sleep recordings, after adjustment for amplitude differences, especially for scoring Stage N3 sleep. [ABSTRACT FROM AUTHOR]
- Subjects :
- SLEEP stages
ELECTROENCEPHALOGRAPHY
POLYSOMNOGRAPHY
ADULTS
ELECTRODES
Subjects
Details
- Language :
- English
- ISSN :
- 09621105
- Volume :
- 33
- Issue :
- 2
- Database :
- Complementary Index
- Journal :
- Journal of Sleep Research
- Publication Type :
- Academic Journal
- Accession number :
- 176081327
- Full Text :
- https://doi.org/10.1111/jsr.13977