Back to Search Start Over

Comparison of Liquid-Based Preparations with Conventional Smears in Thyroid Fine-Needle Aspirates: A Systematic Review and Meta-Analysis.

Authors :
Kang, Yun Jin
Lee, Hyeon Woo
Stybayeva, Gulnaz
Hwang, Se Hwan
Source :
Cancers; Feb2024, Vol. 16 Issue 4, p751, 18p
Publication Year :
2024

Abstract

Simple Summary: We compared the diagnostic accuracy of conventional smears and liquid-based preparations for detecting thyroid lesions using fine-needle aspiration cytology. We reviewed 15,861 samples from 17 studies. There was no significant difference between conventional smears and liquid-based preparations in terms of diagnostic accuracy or the proportion of inadequate smears. SurePath outperformed ThinPrep in terms of diagnostic accuracy among the liquid-based preparations. Recommendations for one method over another should take cost, feasibility, and accuracy into account, necessitating additional research. Background: To compare conventional smears (CSs) and liquid-based preparations (LBPs) for diagnosing thyroid malignant or suspicious lesions. Methods: Studies in the PubMed, SCOPUS, Embase, Web of Science, and Cochrane database published up to December 2023. We reviewed 17 studies, including 15,861 samples. Results: The diagnostic odds ratio (DOR) for CS was 23.6674. The area under the summary receiver operating characteristic curve (AUC) was 0.879, with sensitivity, specificity, negative predictive value, and positive predictive value of 0.8266, 0.8668, 0.8969, and 0.7841, respectively. The rate of inadequate specimens was 0.1280. For LBP, the DOR was 25.3587, with an AUC of 0.865. The sensitivity, specificity, negative predictive value, and positive predictive value were 0.8190, 0.8833, 0.8515, and 0.8562. The rate of inadequate specimens was 0.1729. For CS plus LBP, the AUC was 0.813, with a lower DOR of 9.4557 compared to individual methods. Diagnostic accuracy did not significantly differ among CS, LBP, and CS plus LBP. Subgroup analysis was used to compare ThinPrep and SurePath. The DORs were 29.1494 and 19.7734. SurePath had a significantly higher AUC. Conclusions: There was no significant difference in diagnostic accuracy or proportion of inadequate smears between CS and LBP. SurePath demonstrated higher diagnostic accuracy than ThinPrep. Recommendations for fine-needle aspiration cytology should consider cost, feasibility, and accuracy. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20726694
Volume :
16
Issue :
4
Database :
Complementary Index
Journal :
Cancers
Publication Type :
Academic Journal
Accession number :
175650745
Full Text :
https://doi.org/10.3390/cancers16040751