Back to Search Start Over

Artificial intelligence-based fluid quantification and associated visual outcomes in a real-world, multicentre neovascular age-related macular degeneration national database.

Authors :
Martin-Pinardel, Ruben
Izquierdo-Serra, Jordi
De Zanet, Sandro
Parrado-Carrillo, Alba
Garay-Aramburu, Gonzaga
Puzo, Martin
Arruabarrena, Carolina
Sararols, Laura
Abraldes, Maximino
Broc, Laura
Escobar-Barranco, Jose Juan
Figueroa, Marta
Zapata, Miguel Angel
Ruiz-Moreno, José M.
Moll-Udina, Aina
Bernal-Morales, Carolina
Alforja, Socorro
Figueras-Roca, Marc
Gómez-Baldó, Laia
Ciller, Carlos
Source :
British Journal of Ophthalmology; Feb2024, Vol. 108 Issue 2, p253-262, 10p
Publication Year :
2024

Abstract

Aim To explore associations between artificial intelligence (AI)-based fluid compartment quantifications and 12 months visual outcomes in OCT images from a real-world, multicentre, national cohort of naïve neovascular age-related macular degeneration (nAMD) treated eyes. Methods Demographics, visual acuity (VA), drug and number of injections data were collected using a validated web-based tool. Fluid compartment quantifications including intraretinal fluid (IRF), subretinal fluid (SRF) and pigment epithelial detachment (PED) in the fovea (1 mm), parafovea (3 mm) and perifovea (6 mm) were measured in nanoliters (nL) using a validated AI-tool. Results 452 naïve nAMD eyes presented a mean VA gain of +5.5 letters with a median of 7 injections over 12 months. Baseline foveal IRF associated poorer baseline (44.7 vs 63.4 letters) and final VA (52.1 vs 69.1), SRF better final VA (67.1 vs 59.0) and greater VA gains (+7.1 vs +1.9), and PED poorer baseline (48.8 vs 57.3) and final VA (55.1 vs 64.1). Predicted VA gains were greater for foveal SRF (+6.2 vs +0.6), parafoveal SRF (+6.9 vs +1.3), perifoveal SRF (+6.2 vs -0.1) and parafoveal IRF (+7.4 vs +3.6, all p<0.05). Fluid dynamics analysis revealed the greatest relative volume reduction for foveal SRF (-16.4 nL, -86.8%), followed by IRF (-17.2 nL, -84.7%) and PED (-19.1 nL, -28.6%). Subgroup analysis showed greater reductions in eyes with higher number of injections. Conclusion This real-world study describes an AI-based analysis of fluid dynamics and defines baseline OCT-based patient profiles that associate 12-month visual outcomes in a large cohort of treated naïve nAMD eyes nationwide. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00071161
Volume :
108
Issue :
2
Database :
Complementary Index
Journal :
British Journal of Ophthalmology
Publication Type :
Academic Journal
Accession number :
175623428
Full Text :
https://doi.org/10.1136/bjo-2022-322297