Preoperative estimation of retinal hole location using ultra-wide-field imaging.
- Source :
- Annals of Medicine; 2023, Vol. 55 Issue 2, p1-7, 7p
- Publication Year :
- 2023
-
Abstract
- Accurate localization of retinal holes is essential for successful scleral buckling (SB) surgery. We aimed to verify the feasibility of using ultra-wide-field (UWF) imaging for preoperative estimation of retinal hole location. We observed 21 eyes from 21 patients with rhegmatogenous retinal detachment (RRD) who underwent successful SB. They were treated at the Department of Ophthalmology of the Second Hospital of Hebei Medical University between November 2020 and November 2021. UWF fundus photography using an Optos device was performed at different steering positions 1 day before, 1 day after, and 1 month after SB. Using the preoperative fundus images, we measured the transverse diameter of the optic disc (D1) and the distance from the centre of the retinal holes to the ora serrata (D2). The accurate transverse diameter of the optic disc (Dd) was measured preoperatively using optical coherence tomography. The same surgeon measured the scleral chord lengths intraoperatively from the limbus to the located retinal hole marked on the sclera using an ophthalmic calliper. Statistical software was used to analyze the consistency of scleral chord length between the retinal hole and the limbus, which was estimated by preoperative UWF imaging and was measured using an ophthalmic calliper intraoperatively. There was no statistically significant difference in the scleral chord length between the retinal holes and the limbus, which was estimated by preoperative UWF fundus photography and was measured by the calliper during surgery. It is feasible to locate retinal holes using UWF fundus photography before SB, which is helpful for quick localization, thereby reducing the learning curve of SB surgery. Preoperative ultra-wide-field imaging can provide abundant information about retinal holes and is helpful for assessing their location before surgery. In this prospective cohort study of 21 patients, 25 retinal holes in four quadrants were observed. Axial length and the position of the holes have little impact on preoperative ultra-wide field imaging assessment. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 07853890
- Volume :
- 55
- Issue :
- 2
- Database :
- Complementary Index
- Journal :
- Annals of Medicine
- Publication Type :
- Academic Journal
- Accession number :
- 175571290
- Full Text :
- https://doi.org/10.1080/07853890.2023.2258790