Abstract
- Simple Summary: Non-calcified mammographic findings, which are suspicious for breast cancer, often undergo ultrasound for further evaluation and to facilitate percutaneous tissue sampling. Most of these findings have a correlation with ultrasound examinations, but some do not. The significance of those without an ultrasound correlation has not been evaluated with modern mammographic techniques. Specifically, mammographic architectural distortion is of particular interest given that it is more commonly identified with digital breast tomosynthesis, a modern quasi-three-dimensional mammographic technique. This article serves to provide management guidance for those situations by retrospectively evaluating a very large cohort of these findings. Suspicious non-calcified mammographic findings have not been evaluated with modern mammographic technique, and the purpose of this work is to compare the likelihood of malignancy for those findings. To do this, 5018 consecutive mammographically guided biopsies performed during 2016–2019 at a large metropolitan, community-based hospital system were retrospectively reviewed. In total, 4396 were excluded for targeting calcifications, insufficient follow-up, or missing data. Thirty-seven of 126 masses (29.4%) were malignant, 44 of 194 asymmetries (22.7%) were malignant, and 77 of 302 architectural distortions (AD, 25.5%) were malignant. The combined likelihood of malignancy was 25.4%. Older age was associated with a higher likelihood of malignancy for each imaging finding type (all p ≤ 0.006), and a possible ultrasound correlation was associated with a higher likelihood of malignancy when all findings were considered together (p = 0.012). Two-view asymmetries were more frequently malignant than one-view asymmetries (p = 0.03). There were two false-negative biopsies (98.7% sensitivity and 100% specificity). In conclusion, the 25.4% likelihood of malignancy confirms the recommendation for biopsy of suspicious, ultrasound-occult, mammographic findings. Mammographically guided biopsies were highly sensitive and specific in this study. Older patient age and a possible ultrasound correlation should raise concern given the increased likelihood of malignancy in those scenarios. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 20726694
- Volume :
- 16
- Issue :
- 3
- Database :
- Complementary Index
- Journal :
- Cancers
- Publication Type :
- Academic Journal
- Accession number :
- 175373922
- Full Text :
- https://doi.org/10.3390/cancers16030655