Back to Search Start Over

Excimer laser coronary atherectomy with distal protection for neoatherosclerosis rupture: a case report.

Authors :
Watanabe, Nobuhiro
Yamamoto, Hiroyuki
Kawahara, Kunimitsu
Takaya, Tomofumi
Source :
European Heart Journal Case Reports; Jan2024, Vol. 8 Issue 1, p1-6, 6p
Publication Year :
2024

Abstract

Background Neoatherosclerosis, a prominent contributor to in-stent restenosis (ISR), persists as a formidable challenge during percutaneous coronary intervention. Excimer laser coronary atherectomy (ELCA) and embolic protection devices may help reduce coronary flow disturbance from procedure-related distal embolization. Case summary A 71-year-old man experienced in-stent neoatherosclerosis rupture–related non-ST segment elevation myocardial infarction. Multidisciplinary intracoronary imaging, including intravascular ultrasound and optical coherence tomography (OCT), suggested that the ISR was caused by a neoatherosclerosis rupture that can potentially lead to distal embolization. Excimer laser coronary atherectomy (fluence, 45 mJ/mm<superscript>2</superscript> and frequency, 25 pulse/s) using a 1.7 mm concentric catheter was performed with distal protection using Filtrap (Nipro Corporation, Tokyo, Japan), which significantly reduced the volume of the neoatherosclerosis. However, subsequent ELCA on the highest setting (fluence, 60 mJ/mm<superscript>2</superscript> and frequency, 40 pulse/s) led to a filter no-reflow phenomenon, although OCT revealed a further effective vaporization of the neoatherosclerosis and an apparent reduction of soft tissue compatible with the thrombus. After removing the embolic protection device, drug-coated balloon angioplasty provided optimal results without coronary flow disturbance. Discussion Excimer laser coronary atherectomy reduces soft plaque and thrombus burden, which can reduce the occurrence of distal embolization in select cases. In the case of this patient, procedure-related distal embolization may have been induced by the heightened photomechanical effects resulting from the use of the highest setting in ELCA under increased intracoronary arterial pressure caused by continuous saline injection during ELCA. Concomitant distal protection during ELCA may be more feasible for preventing coronary flow disturbance in patients with a large amount of neoatherosclerosis. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
25142119
Volume :
8
Issue :
1
Database :
Complementary Index
Journal :
European Heart Journal Case Reports
Publication Type :
Academic Journal
Accession number :
175158245
Full Text :
https://doi.org/10.1093/ehjcr/ytad626