Back to Search Start Over

Deep learning model for measuring the sagittal Cobb angle on cervical spine computed tomography.

Authors :
Wang, Chunjie
Ni, Ming
Tian, Shuai
Ouyang, Hanqiang
Liu, Xiaoming
Fan, Lianxi
Dong, Pei
Jiang, Liang
Lang, Ning
Yuan, Huishu
Source :
BMC Medical Imaging; 11/28/2023, Vol. 23 Issue 1, p1-9, 9p
Publication Year :
2023

Abstract

Purposes: To develop a deep learning (DL) model to measure the sagittal Cobb angle of the cervical spine on computed tomography (CT). Materials and methods: Two VB-Net-based DL models for cervical vertebra segmentation and key-point detection were developed. Four-points and line-fitting methods were used to calculate the sagittal Cobb angle automatically. The average value of the sagittal Cobb angle was manually measured by two doctors as the reference standard. The percentage of correct key points (PCK), matched samples t test, intraclass correlation coefficient (ICC), Pearson correlation coefficient, mean absolute error (MAE), and Bland‒Altman plots were used to evaluate the performance of the DL model and the robustness and generalization of the model on the external test set. Results: A total of 991 patients were included in the internal data set, and 112 patients were included in the external data set. The PCK of the DL model ranged from 78 to 100% in the test set. The four-points method, line-fitting method, and reference standard measured sagittal Cobb angles were − 1.10 ± 18.29°, 0.30 ± 13.36°, and 0.50 ± 12.83° in the internal test set and 4.55 ± 20.01°, 3.66 ± 18.55°, and 1.83 ± 12.02° in the external test set, respectively. The sagittal Cobb angle calculated by the four-points method and the line-fitting method maintained high consistency with the reference standard (internal test set: ICC = 0.75 and 0.97; r = 0.64 and 0.94; MAE = 5.42° and 3.23°, respectively; external test set: ICC = 0.74 and 0.80, r = 0.66 and 0.974, MAE = 5.25° and 4.68°, respectively). Conclusions: The DL model can accurately measure the sagittal Cobb angle of the cervical spine on CT. The line-fitting method shows a higher consistency with the doctors and a minor average absolute error. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14712342
Volume :
23
Issue :
1
Database :
Complementary Index
Journal :
BMC Medical Imaging
Publication Type :
Academic Journal
Accession number :
173890523
Full Text :
https://doi.org/10.1186/s12880-023-01156-6