Back to Search Start Over

Processing and Properties of Single-Crystal Copper Wire.

Authors :
Cao, Jun
Wu, Xuefeng
Su, Chenghao
Jia, Hewei
Sun, Yongzhen
Source :
Micromachines; Nov2023, Vol. 14 Issue 11, p2080, 13p
Publication Year :
2023

Abstract

The effects of drawing parameters and annealing process on the properties and microstructure of single crystal copper wire are studied using a wire-drawing machine, heat-treatment equipment, microcomputer-controlled electronic universal tester, resistance tester, and scanning electron microscope. The results show that, after drawing the single-crystal copper wire with a single-pass deformation of 14%, the grains elongate along the tensile direction, tensile strength increases from 500.83 MPa to 615.5 Mpa, and resistivity changes from 1.745 × 10<superscript>−8</superscript> Ω·m to 1.732 × 10<superscript>−8</superscript> Ω·m. After drawing at a drawing rate of 500 m/min, the degree of grain refinement increases and tensile strength increases from 615.5 Mpa to 660.26 Mpa. When a copper wire of Φ0.08 mm is annealed, its tensile strength decreases from 660.26 Mpa to 224.7 Mpa, and elongation increases from 1.494% to 19.87% when the annealing temperature increases to 400 °C. When the annealing temperature increases to 550 °C, the tensile strength and elongation decrease to 214.4 MPa and 12.18%, respectively. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
2072666X
Volume :
14
Issue :
11
Database :
Complementary Index
Journal :
Micromachines
Publication Type :
Academic Journal
Accession number :
173864244
Full Text :
https://doi.org/10.3390/mi14112080