Back to Search Start Over

Tandem-column extraction chromatography for Nd separation: minimizing mass-independent isotope fractionation for ultrahigh-precision Nd isotope-ratio analysis.

Authors :
Wang, Da
Carlson, Richard W.
Source :
JAAS (Journal of Analytical Atomic Spectrometry); 1/1/2022, Vol. 37 Issue 1, p185-193, 9p
Publication Year :
2022

Abstract

The short-lived <superscript>146</superscript>Sm–<superscript>142</superscript>Nd isotope system traces key early planetary differentiation processes that occurred during the first 500 million-years of the solar system history. The variations of <superscript>142</superscript>Nd/<superscript>144</superscript>Nd in terrestrial samples, typically within a range of ±20 ppm, are determined using high-precision mass spectrometry that requires quantitative separation of Nd from all other elements in the sample, including the neighboring lanthanides. Recent improvements in mass spectrometry have pushed the analytical precision of <superscript>142</superscript>Nd/<superscript>144</superscript>Nd measurements down to ∼2 ppm. Non-mass-dependent isotope fractionation produced during Nd separation, however, is a major factor limiting the quality of the <superscript>142</superscript>Nd data. Popular chemical separation methods using Ln resins have unpredictable nuclear field shift effects that generate anomalous Nd isotope ratios. In order to solve this problem and potentially resolve small <superscript>142</superscript>Nd/<superscript>144</superscript>Nd variations within ±5 ppm, in this study, we present a new two-step column separation method that effectively removes the isobaric interferents of Ce, Pr and Sm, with a recovery rate of Nd greater than 98%. JNdi-1 standard solutions doped with these interfering elements and geological reference materials are tested to document the performance of this method. A set of titanite samples from the Pilbara Craton in western Australia were also investigated to test the potential isotope fractionation effects. The same samples were processed using our method and the widely used Ln method. In contrast to the nuclear field shift effects observed from the samples using the Ln method, the results based on our new method show no detectable isotope fractionation, which further confirms the reliability of this new column chemistry scheme that is optimized for ppm-level precision Nd isotope ratio measurement, especially for resolving small variations in <superscript>142</superscript>Nd/<superscript>144</superscript>Nd caused by the decay of <superscript>146</superscript>Sm. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02679477
Volume :
37
Issue :
1
Database :
Complementary Index
Journal :
JAAS (Journal of Analytical Atomic Spectrometry)
Publication Type :
Academic Journal
Accession number :
173532844
Full Text :
https://doi.org/10.1039/d1ja00365h