Back to Search Start Over

Portable fixed dynamometry enables home-based, reliable assessment of muscle strength in patients with amyotrophic lateral sclerosis: a pilot study.

Authors :
Van Unnik, Jordi W. J.
Bakers, Jaap N.E.
Kokx, Steure
Van Den Berg, Leonard H.
Visser-Meily, Johanna M.A.
Beelen, Anita
Van Eijk, Ruben P.A.
Source :
Amyotrophic Lateral Sclerosis & Frontotemporal Degeneration; Nov2023, Vol. 24 Issue 7/8, p651-660, 10p
Publication Year :
2023

Abstract

To determine the feasibility, reliability, and sensitivity of remotely monitoring muscle strength loss of knee extensors using a novel portable fixed dynamometer (PFD) in patients with amyotrophic lateral sclerosis (ALS). We conducted a pilot study with a newly developed device to measure knee extension strength. Patients performed unsupervised PFD measurements, biweekly, for 6 months at home. We evaluated feasibility using adherence and a device-specific questionnaire. Reliability was assessed by (1) comparing unsupervised and supervised measurements to identify systematic bias, and (2) comparing consecutive unsupervised measurements to determine test-retest reliability expressed as intraclass correlation coefficient (ICC) and standard error of measurement (SEM). Sensitivity to detect longitudinal change was described using linear mixed-effects models. We enrolled 18 patients with ALS. Adherence was 86%, where all patients found that the device suitable to measure muscle strength at home; 4 patients (24%) found the measurements burdensome. The correlation between (un)supervised measurements was excellent (Pearson's r 0.97, 95%CI; 0.94 − 0.99) and no systematic bias was present (mean difference 0.13, 95%CI; −2.22 − 2.48, p = 0.91). Unsupervised measurements had excellent test-retest reliability with an average ICC of 0.97 (95%CI: 0.94 − 0.99) and SEM of 5.8% (95%CI: 4.8 − 7.0). Muscle strength declined monthly by 1.9 %predicted points (95%CI; −3.0 to −0.9, p = 0.001). Using the PFD, it proved feasible to perform knee extension strength measurements at home which were reliable and sensitive for detecting muscle strength loss. Larger studies are warranted to compare the device with conventional outcomes. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
21678421
Volume :
24
Issue :
7/8
Database :
Complementary Index
Journal :
Amyotrophic Lateral Sclerosis & Frontotemporal Degeneration
Publication Type :
Academic Journal
Accession number :
173321438
Full Text :
https://doi.org/10.1080/21678421.2023.2231494