Back to Search Start Over

FP12 Pulsed Cold Neutron Beam Line for Fundamental Nuclear Physics at LANSCE.

Authors :
Seo, P.-N.
Bowman, J. D.
Dabaghyan, M.
Gericke, M.
Gillis, R. C.
Greene, G. L.
Leuschner, M. B.
Long, J.
Mahurin, R.
Mitchell, G. S.
Nann, H.
Page, S. A.
Penttila, S. I.
Peralta, G.
Ramsay, W. D.
Santra, S.
Sharapov, E. I.
Wilburn, W. S.
Source :
AIP Conference Proceedings; 2005, Vol. 769 Issue 1, p700-703, 4p
Publication Year :
2005

Abstract

A new pulsed cold neutron beam line, flight path 12, has been commissioned at LANSCE by the NPDGamma collaboration. The beam line was designed for fundamental nuclear physics experiments. We present the measured brightness of the unique backscattering moderator viewed by the flight path 12 neutron guide and report results for guide performance measurements. The peak neutron flux out of the guide is dN/dE= 2.4×105 neutrons/meV/cm2/s/μA at 2 meV neutron energy. © 2005 American Institute of Physics [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
769
Issue :
1
Database :
Complementary Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
17307261
Full Text :
https://doi.org/10.1063/1.1945105