Back to Search Start Over

Simulation analysis of gas–solid flow characteristics and water evaporation in flue gas semi‐dry desulphurization process based on CPFD method.

Authors :
Liu, Peng
Wu, Xuan
Li, Haiguang
Bo, Yuxuan
Wei, Nan
Source :
Canadian Journal of Chemical Engineering; Nov2023, Vol. 101 Issue 11, p6352-6371, 20p
Publication Year :
2023

Abstract

The gas–solids flow in an industrial‐scale semi‐dry method desulphurization tower is simulated by the computational particle fluid dynamics (CPFD) approach. Compared with previous studies on desulphurization towers, this study focuses on analyzing particle distribution characteristics such as particle volume fraction, temperature distribution, and residence time. The simulation fully considered the particle–fluid, particle–particle, and particle–wall interactions in the desulphurization tower. Based on these considerations, the effects of flue gas inlet velocity and temperature on the gas–solid distribution characteristics of the desulphurization tower are simulated. An optimization scheme for adjusting the gas–solid flow in the desulphurization tower is proposed. The research results show that the error between the CPFD simulation data and experimental data is small and the changing trend is consistent. The particles in the bed of the desulphurization tower show a typical core–annulus flow. The distribution of gas and particles in the bed has a serious deviation with the increase of the flue gas inlet velocity and temperature. As the axial height of the desulphurization tower increases, the flue gas velocity, temperature, particle concentration, and water vapour distribution in the bed become more uniform. The relatively stable operating conditions for the gas–solid flow in the desulphurization tower is that the flue gas inlet velocity and temperature are 15 m/s and 393 K, respectively. Under these operating conditions, the pressure loss caused by the venturi accounted for 73.6% of the total pressure loss of the desulphurization tower. When the particle radius is between 0–150 μm, the particle size and the flue gas inlet velocity have the greatest influence on the particle residence time. Finally, the distribution of gas and particles before and after the adjustment of the desulphurization tower is compared, which showed that adjusting the bottom structure of the desulphurization tower could optimize the gas–solid flow. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00084034
Volume :
101
Issue :
11
Database :
Complementary Index
Journal :
Canadian Journal of Chemical Engineering
Publication Type :
Academic Journal
Accession number :
172804599
Full Text :
https://doi.org/10.1002/cjce.24888