Back to Search Start Over

Ab-externo canaloplasty with and without suture in highly myopic eyes.

Authors :
Urcola, Javier Aritz
Illarramendi, Igor
Lauzirika, Gorka
Source :
International Ophthalmology; Oct2023, Vol. 43 Issue 10, p3695-3705, 11p
Publication Year :
2023

Abstract

Purpose: To evaluate the effectiveness of ab-externo canaloplasty using the iTrack canaloplasty microcatheter (Nova Eye Inc, Fremont, California), with or without suture, in glaucoma patients with high myopia. Methods: This was a prospective, single-center, single-surgeon, observational study comparing the outcomes of ab-externo canaloplasty performed with a tensioning suture (suture group) and without a tensioning suture (no-suture group) in mild to severe glaucoma patients with high myopia. Twenty-three eyes received canaloplasty as a standalone procedure, 5 in combination with phacoemulsification. Primary efficacy endpoints included intraocular pressure (IOP) and the number of glaucoma medications. Safety was assessed based on reported complications and adverse events. Results: Twenty-nine eyes of 29 patients with a mean age of 61.2 ± 12.3 years; 19 eyes in the no-suture group and 10 eyes in the suture group. All eyes demonstrated a significant reduction in IOP 24 months postoperatively, from 21.9 ± 7.22 to 15.4 ± 4.86 mmHg in the suture group and from 23.8 ± 7.58 to 19.7 ± 3.68 mmHg in the no-suture group. The mean number of anti-glaucoma medications reduced from 3.1 ± 0.6 to 0.4 ± 0.7 in the suture group and 3.3 ± 0.9 to and 0.2 ± 0.6 in the no-suture group at 24 months. IOP was not significantly different at baseline between the 2 groups, but it was statistically different at 12 and 24 months. There was no statistically significant difference in the number of medications between the groups at baseline, 12 and 24 months. No serious complications were reported. Conclusion: Ab-externo canaloplasty performed either with or without a tensioning suture demonstrated good effectiveness in highly myopic eyes with a significant reduction in IOP and number of anti-glaucoma medications. The suture group achieved a lower postoperative IOP. However, the no-suture modification provides a similar reduction in medications with reduced tissue handling. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01655701
Volume :
43
Issue :
10
Database :
Complementary Index
Journal :
International Ophthalmology
Publication Type :
Academic Journal
Accession number :
171994182
Full Text :
https://doi.org/10.1007/s10792-023-02779-y