Back to Search Start Over

Retrospective comparison of long-term functionality and revision rate of two different shunt valves in pediatric and adult patients.

Authors :
Busse, Lewin-Caspar
Dubinski, Daniel
Gessler, Florian
Dinc, Nazife
Konczalla, Jürgen
Czabanka, Marcus
Senft, Christian
Freiman, Thomas M.
Baumgarten, Peter
Source :
Acta Neurochirurgica; Sep2023, Vol. 165 Issue 9, p2541-2549, 9p
Publication Year :
2023

Abstract

Purpose: The most frequent therapy of hydrocephalus is implantation of ventriculoperitoneal shunts for diverting cerebrospinal into the peritoneal cavity. We compared two adjustable valves, proGAV and proGAV 2.0, for complications resulting in revision surgery. Methods: Four hundred patients undergoing primary shunt implantation between 2014 and 2020 were analyzed for overall revision rate, 1-year revision rate, and revision-free survival observing patient age, sex, etiology of hydrocephalus, implantation site, prior diversion of cerebrospinal fluid, and cause of revision. Results: All data were available of all 400 patients (female/male 208/192). Overall, 99 patients underwent revision surgery after primary implantation. proGAV valve was implanted in 283 patients, and proGAV 2.0 valves were implanted in 117 patients. There was no significant difference between the two shunt valves concerning revision rate (p = 0.8069), 1-year revision rate (p = 0.9077), revision-free survival (p = 0.6921), and overall survival (p = 0.3232). Regarding 1-year revision rate, we observed no significant difference between the two shunt valves in pediatric patients (40.7% vs 27.6%; p = 0.2247). Revision operation had to be performed more frequently in pediatric patients (46.6% vs 24.8%; p = 0.0093) with a significant higher number of total revisions with proGAV than proGAV 2.0 (33 of 59 implanted shunts [55.9%] vs. 8 of 29 implanted shunts [27.6%]; p = 0.0110) most likely due to longer follow-up in the proGAV-group. For this reason, we clearly put emphasis on analyzing results regarding 1-year revision rate. Conclusion: According to the target variables we analyzed, aside from lifetime revision rate in pediatric patients, there is no significant difference between the two shunt valves. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00016268
Volume :
165
Issue :
9
Database :
Complementary Index
Journal :
Acta Neurochirurgica
Publication Type :
Academic Journal
Accession number :
171364915
Full Text :
https://doi.org/10.1007/s00701-023-05719-y