THE EXPERIMENTAL EVALUATION OF TENSILE FORCES IN STAYS OF A CABLE-STAYED FOOTBRIDGE.

Authors :
BOHÁČOVÁ, MAGDALÉNA
Source :
Acta Polytechnica CTU Proceedings; 2023, Vol. 40, p1-7, 7p
Publication Year :
2023

Abstract

The topic of this paper is an experimental analysis of the dynamic behaviour of stays of an existing footbridge focusing on determination of the tensile forces in stays. The examined structure was the footbridge across the Vltava river in Lužec nad Vltavou. It is a cable-stayed footbridge, the horizontal load-bearing structure consists of UHPC components, which are prestressed by a pair of external cables. The horizontal load-bearing structure is suspended on a 39.85m high A-shaped steel pylon by means of a system of 17 pairs of stays. As a part of the work the tensile forces in stays were determined using the vibration frequency method. The method is based on the knowledge of natural frequencies of the stays, which were investigated by the experimental analysis. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
23365382
Volume :
40
Database :
Complementary Index
Journal :
Acta Polytechnica CTU Proceedings
Publication Type :
Academic Journal
Accession number :
170036957
Full Text :
https://doi.org/10.14311/APP.2023.40.0001