Effects of thickness and polishing treatment on the translucency and opalescence of six dental CAD-CAM monolithic restorative materials: an in vitro study.
- Source :
- BMC Oral Health; 8/19/2023, Vol. 23 Issue 1, p1-12, 12p
- Publication Year :
- 2023
-
Abstract
- Background: Computer-aided design and computer-aided manufacturing (CAD-CAM) materials for prosthetic is gaining popularity in dentistry. However, limited information exists regarding the impact of thickness and roughening treatment on the optical properties of contemporary CAD-CAM restorative materials. This study aimed to quantitatively evaluate the translucency and opalescence of six dental CAD-CAM materials in response to different thicknesses and roughening treatments. Methods: Six dental CAD-CAM materials, lithium disilicate glass–ceramic (IPS e.max CAD, LS), polymer-infiltrated ceramic (VITA Enamic, VE), resin-nano ceramic glass–ceramic (LAVA Ultimate, LU), polymethyl methacrylate (Telio CAD, TE), and two zirconia reinforced lithium silicate (VITA Suprinity, VS, and Celtra Duo, CD), in shade A2 were prepared as 12 × 12mm<superscript>2</superscript> specimens of four thicknesses (0.5mm, 1.0mm, 1.5mm, and 2.0mm) (N = 240, n = 10). After three different treatments (polished, roughened by SiC P800-grit, and SiC P300-grit), the translucency parameter (TP<subscript>00</subscript>) and opalescence parameter (OP) were measured with a spectrophotometer (VITA Easyshade V). The surface roughness was analyzed with a shape measurement laser microscope. The data were analyzed using a MANOVA, post hoc Tukey–Kramer test, the t test, and regression analysis (α =.05). Results: The TP<subscript>00</subscript> and OP were significantly influenced by material type, thickness and roughening treatment (P <.05). TP<subscript>00</subscript> showed a continues decline with increasing thicknesses, while the variations of OP were material-dependent. TP<subscript>00</subscript> ranged from 37.80 (LS in 0.5mm) to 5.66 (VS in 2.0mm), and OP ranged from 5.66 (LU in 0.5mm) to 9.55 (VS in 0.5mm). The variations in TP<subscript>00</subscript> of all materials between adjacent thicknesses ranged from 2.10 to 15.29, exceeding the acceptable translucency threshold except for LU. Quadratic and logarithmic regression curves exhibited the best fit for TP<subscript>00</subscript> among the materials. Compared to polished specimens, rougher specimens exhibited lower TP00 and higher OP in all materials except for LS (P < 0.05). Roughening with P300-grit decreased TP<subscript>00</subscript> and OP by an average of 2.59 and 0.43 for 0.5mm specimens, and 1.26 and 0.25 for 2.0mm specimens, respectively. Conclusions: Variations in translucency caused by thickness and roughening treatment were perceptible and may be clinically unacceptable. Careful consideration should be given to the selection of CAD-CAM materials based on their distinct optical properties. [ABSTRACT FROM AUTHOR]
- Subjects :
- DENTURE equipment
DENTAL technology
LITHIUM compounds
STATISTICS
IN vitro studies
COMPUTER-aided design
SPECTROPHOTOMETERS
ANALYSIS of variance
DENTAL materials
MULTIVARIATE analysis
MICROSCOPY
COSMETIC dentistry
QUANTITATIVE research
REGRESSION analysis
T-test (Statistics)
TEETH polishing
RESEARCH funding
DESCRIPTIVE statistics
POLYMERS
DENTAL translucency
DENTAL fillings
DATA analysis
DATA analysis software
DENTAL cements
EQUIPMENT & supplies
Subjects
Details
- Language :
- English
- ISSN :
- 14726831
- Volume :
- 23
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- BMC Oral Health
- Publication Type :
- Academic Journal
- Accession number :
- 170027703
- Full Text :
- https://doi.org/10.1186/s12903-023-03299-y