Back to Search
Start Over
Differential diagnosis of adrenal adenomas and metastases using spectral parameters in dual-layer detector spectral CT.
- Source :
- Journal of Cancer Research & Clinical Oncology; Sep2023, Vol. 149 Issue 12, p10453-10463, 11p
- Publication Year :
- 2023
-
Abstract
- Objective: To assess the diagnostic value of spectral parameters in differentiating adrenal adenomas from metastases based on dual-layer detector spectral CT (DLSCT). Materials and methods: Patients with adenomas or metastases who underwent enhanced DLSCT of the adrenals were enrolled. The CT values of virtual non-contrast images (CT<subscript>VNC</subscript>), iodine density (ID) values, and Z-effective (Z-eff) values, the normalized iodine density (NID) values, slopes of spectral HU curves (s-SHC), and iodine-to-CT<subscript>VNC</subscript> ratios of the tumors were measured in each phase. Receiver operating characteristic (ROC) curves were used to compare the diagnostic values. Results: Ninety-nine patients with 106 adrenal lesions (63 adenomas, 43 metastases) were included. In the venous phase, all spectral parameters were significantly different between adenomas and metastases (all p < 0.05). The combined spectral parameters showed a better diagnostic performance in the venous phase than in other phase (p < 0.05). The iodine-to-CT<subscript>VNC</subscript> value had a larger area under the ROC curve (AUC) than the other spectral parameters in the differential diagnosis of adenomas and metastases, with a diagnostic sensitivity and specificity of 74.4% and 91.9%, respectively. In the differential diagnosis of lipid-rich adenomas, lipid-poor adenomas and metastases, the CT<subscript>VNC</subscript> value and s-SHC value also had a larger AUC than the other spectral parameters, with a diagnostic sensitivity of 97.7%, 79.1% and specificity of 91.2%, 93.1%, respectively. Conclusion: On DLSCT, the combined spectral parameters in the venous phase could help better distinguish adrenal adenomas from metastases. The iodine-to-CT<subscript>VNC</subscript>, CT<subscript>VNC</subscript> and s-SHC values had the highest AUC values in differentiating adenomas, lipid-rich adenomas and lipid-poor adenomas from metastases, respectively. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 01715216
- Volume :
- 149
- Issue :
- 12
- Database :
- Complementary Index
- Journal :
- Journal of Cancer Research & Clinical Oncology
- Publication Type :
- Academic Journal
- Accession number :
- 169911515
- Full Text :
- https://doi.org/10.1007/s00432-023-04931-8