Contour‐guided deep learning based deformable image registration for dose monitoring during CBCT‐guided radiotherapy of prostate cancer.

Authors :
Hemon, Cédric
Rigaud, Bastien
Barateau, Anais
Tilquin, Florian
Noblet, Vincent
Sarrut, David
Meyer, Philippe
Bert, Julien
De Crevoisier, Renaud
Simon, Antoine
Source :
Journal of Applied Clinical Medical Physics; Aug2023, Vol. 24 Issue 8, p1-10, 10p
Publication Year :
2023

Abstract

Purpose: To evaluate deep learning (DL)‐based deformable image registration (DIR) for dose accumulation during radiotherapy of prostate cancer patients. Methods and Materials: Data including 341 CBCTs (209 daily, 132 weekly) and 23 planning CTs from 23 patients was retrospectively analyzed. Anatomical deformation during treatment was estimated using free‐form deformation (FFD) method from Elastix and DL‐based VoxelMorph approaches. The VoxelMorph method was investigated using anatomical scans (VMorph_Sc) or label images (VMorph_Msk), or the combination of both (VMorph_Sc_Msk). Accumulated doses were compared with the planning dose. Results: The DSC ranges, averaged for prostate, rectum and bladder, were 0.60–0.71, 0.67–0.79, 0.93–0.98, and 0.89–0.96 for the FFD, VMorph_Sc, VMorph_Msk, and VMorph_Sc_Msk methods, respectively. When including both anatomical and label images, VoxelMorph estimated more complex deformations resulting in heterogeneous determinant of Jacobian and higher percentage of deformation vector field (DVF) folding (up to a mean value of 1.90% in the prostate). Large differences were observed between DL‐based methods regarding estimation of the accumulated dose, showing systematic overdosage and underdosage of the bladder and rectum, respectively. The difference between planned mean dose and accumulated mean dose with VMorph_Sc_Msk reached a median value of +6.3 Gy for the bladder and −5.1 Gy for the rectum. Conclusion: The estimation of the deformations using DL‐based approach is feasible for male pelvic anatomy but requires the inclusion of anatomical contours to improve organ correspondence. High variability in the estimation of the accumulated dose depending on the deformable strategy suggests further investigation of DL‐based techniques before clinical deployment. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15269914
Volume :
24
Issue :
8
Database :
Complementary Index
Journal :
Journal of Applied Clinical Medical Physics
Publication Type :
Academic Journal
Accession number :
169783493
Full Text :
https://doi.org/10.1002/acm2.13991