Back to Search
Start Over
Effect of Various Dynamic Shear Rheometer Testing Methods on the Measured Rheological Properties of Bitumen.
- Source :
- Materials (1996-1944); Apr2023, Vol. 16 Issue 7, p2745, 15p
- Publication Year :
- 2023
-
Abstract
- A 2<superscript>3</superscript> factorial design experiment was conducted to study the influence of pre-heating temperature (HT) for manufacturing sample, bonding temperature (BT) onto rheometer, and trimming state (Trim) of the sample on complex shear modulus (G*) and phase angle (δ) using a dynamic shear rheometer on unmodified bitumen of types 50/70, 70/100, and two 160/220 from various sources. In addition, the black diagram and 2S2P1D model were used to evaluate the viscoelastic properties of bitumens. Findings show that the G* is more sensitive to the changes than the δ. Additionally, it was found that the 8 mm parallel plate diameter had a higher sensitivity to the trimming state than the 25 mm. The tested factor HT generally did not have a statistically significant impact on the results of the tested materials, except for 160/220_I. At practically all the temperatures tested for 50/70 and 160/220_II, the G* dropped by increasing the factor BT from a lower to a higher value. The Trim:BT interaction has the greatest impact on all materials and temperatures on G*, except for 160/220 at lower temperatures. However, in the case of δ, the Trim:BT interaction has the most significant effects for 70/100 and 160/220_II. The black diagrams show no discernible differences, which may be a result of the limited range of changes made to the variables. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 19961944
- Volume :
- 16
- Issue :
- 7
- Database :
- Complementary Index
- Journal :
- Materials (1996-1944)
- Publication Type :
- Academic Journal
- Accession number :
- 163042473
- Full Text :
- https://doi.org/10.3390/ma16072745