Transcatheter closure of aortocaval fistula with the amplatzer duct occluder.

Authors :
Godart, François
Haulon, Stéphan
Houmany, Mohamed
Francart, Charles
Brevière, Georges-Marie
Rey, Christian
Koussa, Mohamad
Godart, François
Haulon, Stéphan
Brevière, Georges-Marie
Source :
Journal of Endovascular Therapy; Feb2005, Vol. 12 Issue 1, p134-137, 4p, 2 Black and White Photographs
Publication Year :
2005

Abstract

<bold>Purpose: </bold>To report percutaneous closure of aortocaval fistulas with the Amplatzer Duct Occluder. <bold>Case Reports: </bold>An aortocaval fistula was diagnosed after surgical repair of an abdominal aortic aneurysm in a 73-year-old man. A 3-year-old girl was treated for a congenital aortocaval fistula in another case. An 8 x 6-mm Amplatzer Duct Occluder was introduced via a 6-F introducer in each case, successfully occluding the fistulous track. Both patients are well and without any echocardiographic evidence of a shunt at 6 months. <bold>Conclusions: </bold>In selected patients, transcatheter closure of aortocaval fistula with the Amplatzer Duct Occluder could be an alternative to open surgery. Further evaluation is necessary. [ABSTRACT FROM AUTHOR]