Back to Search Start Over

Assessment of health-related quality of life in Australian patients with idiopathic pulmonary fibrosis: a comparison of the EQ-5D-5L and the AQoL-8D.

Authors :
Cox, Ingrid A.
Campbell, Julie
de Graaff, Barbara
Otahal, Petr
Corte, Tamera J.
Moodley, Yuben
Hopkins, Peter
Macansh, Sacha
Walters, E. Haydn
Palmer, Andrew J.
Source :
Quality of Life Research; Feb2023, Vol. 32 Issue 2, p473-493, 21p, 10 Charts, 2 Graphs
Publication Year :
2023

Abstract

Purpose: Idiopathic pulmonary fibrosis (IPF) is a progressive and debilitating chronic lung disease with a high symptom burden, which has a substantial impact on health-related quality of life (HRQoL). Our study aimed to assess the suitability of the EuroQol five-dimension (EQ-5D-5L) and the Assessment of Quality of Life- eight-dimension (AQoL-8D) questionnaires in measuring HRQoL as health state utility values (HSUVs) in an Australian IPF cohort. Methods: Data for estimation of health state utility values (HSUVs) were collected from participants of the Australian IPF Registry (AIPFR) using self-administered surveys which included the EQ-5D-5L and the AQoL-8D. Data on lung function and disease specific HRQoL instruments were collected from the AIPFR. Performance of the two instruments was evaluated based on questionnaire practicality, agreement between the two instruments and test performance (internal and construct validity). Results: Overall completion rates for the EQ-5D-5L and AQoL-8D were 96% and 85%, respectively. Mean (median) HSUVs were 0.65 (0.70) and 0.69 (0.72) for the EQ-5D-5L and AQoL-8D, respectively. There was reasonable agreement between the two instruments based on the Bland–Altman plot mean difference (−0.04) and intraclass correlation coefficient (0.84), however there were some fundamental differences. A larger range of values was observed with the EQ-5D-5L (−0.57–1.00 vs 0.16–1.00). The EQ-5D-5L had a greater divergent sensitivity and efficacy in relation to assessing HSUVs between clinical groupings. The AQoL-8D ,however, had a higher sensitivity to measure psychosocial aspects of HRQoL in IPF. Conclusion: The EQ-5D-5L demonstrated superior performance when compared to AQoL-8D in persons with IPF. This may be attributable to the high symptom burden which is physically debilitating to which the EQ-5D-5L may be more sensitive. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09629343
Volume :
32
Issue :
2
Database :
Complementary Index
Journal :
Quality of Life Research
Publication Type :
Academic Journal
Accession number :
161795341
Full Text :
https://doi.org/10.1007/s11136-022-03205-z