Back to Search Start Over

Pressures do not equal volumes: implications for heart failure management in patients with CardioMEMS.

Authors :
Khan, Muhammad Shahzeb
Khouri, Michel G.
Gomez, Leilani
Fudim, Marat
Source :
ESC Heart Failure; Feb2023, Vol. 10 Issue 1, p716-720, 5p
Publication Year :
2023

Abstract

Pulmonary arterial pressures are often used as surrogates for intravascular blood volume. However, the relationship between pressure and volume remains controversial. To contextualize and provide concrete examples and impact on clinical management, we report two cases of heart failure (one in heart failure with reduced ejection fraction and one in heart failure with preserved ejection fraction) where pressureā€based measurements did not accurately represent the intravascular status and affected clinical management. [ABSTRACT FROM AUTHOR]