Back to Search Start Over

Desalination of groundwater for several districts in Baghdad-Iraq using reverse osmosis membrane.

Authors :
Abbas, Abbas Hadi
H.Lateef, Khalid
Abdeljabbar, Aseel T.
Abbas, Firas S.
Source :
AIP Conference Proceedings; 2022, Vol. 2660 Issue 1, p1-13, 13p
Publication Year :
2022

Abstract

This paper has been achieved to desalinate the brackish groundwater for several districts located in Baghdad the capital of Iraq which are Amiriya, Shurta 5 ,and New Baghdad by using reverse osmosis (RO) Unit. ULP 1812-50 RO type has been used for desalination in this paper. The system has accomplished the percentage of water recovery that ranged between (18.18 - 33.33)% and the percentage of salt rejection that ranged between (97.07 - 99.29)%. As well as the high efficiencies of removal for the physio-chemical parameters of the raw groundwater which are Electrical conductivity, EC (95-99)%, Turbidity(100)%, Total Hardness (100)%, Ca (95-100)%, Mg (84-93)%, Cl (70-96)%, SO<subscript>4</subscript> (85-100)% and NO<subscript>3</subscript> (73-93)%. These results have showed us that the RO technique is suitable to produce freshwater from brackish water. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
2660
Issue :
1
Database :
Complementary Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
160283575
Full Text :
https://doi.org/10.1063/5.0113443