Temporal Change in Anterior Chamber Depth after Combined Vitrectomy and Cataract Surgery Using Different Sizes of Intraocular Lens.
- Source :
- Journal of Clinical Medicine; Nov2022, Vol. 11 Issue 21, p6430, 11p
- Publication Year :
- 2022
-
Abstract
- This study aimed to investigate the temporal changes in the anterior chamber depth (ACD) and refractive prediction error (RPE) of 6 and 7 mm diameter intraocular lenses (IOLs) after cataract surgery or phacovitrectomy with or without sulfur hexafluoride (SF6) gas. We reviewed 120 eyes (120 patients) and divided them into six groups: three groups of cataract surgery alone and phacovitrectomy (with or without SF6), which were further divided according to IOL diameter (6 and 7 mm) used. We examined the ACD and IOL position using a swept-source anterior segment optical coherence tomograph at 1 day, 1 week, and 1 month postoperatively; and the RPE at 1 month postoperatively. The ACD and IOL position at postoperative day 1 in the SF6 injection groups were significantly smaller than those in the other groups (p < 0.01). At 1 week, the ACD and IOL position of the 6 mm IOL SF6 injection group was smaller than those in the other groups (p < 0.01); thus, complications such as synechia or pupillary capture should be considered in the early postopera-tive period of phacovitrectomy with SF6, especially in the 6 mm IOL. The ACD, IOL position, and RPE at 1 month did not significantly differ among the groups, regardless of the IOL diameter or SF6. In the SF6 injection groups, the ACD and IOL position gradually deepened with less gas. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 20770383
- Volume :
- 11
- Issue :
- 21
- Database :
- Complementary Index
- Journal :
- Journal of Clinical Medicine
- Publication Type :
- Academic Journal
- Accession number :
- 160231657
- Full Text :
- https://doi.org/10.3390/jcm11216430