Back to Search Start Over

Accelerating Cardiac Diffusion Tensor Imaging With a U‐Net Based Model: Toward Single Breath‐Hold.

Authors :
Ferreira, Pedro F.
Banerjee, Arjun
Scott, Andrew D.
Khalique, Zohya
Yang, Guang
Rajakulasingam, Ramyah
Dwornik, Maria
De Silva, Ranil
Pennell, Dudley J.
Firmin, David N.
Nielles‐Vallespin, Sonia
Source :
Journal of Magnetic Resonance Imaging; Dec2022, Vol. 56 Issue 6, p1691-1704, 14p
Publication Year :
2022

Abstract

Background: In vivo cardiac diffusion tensor imaging (cDTI) characterizes myocardial microstructure. Despite its potential clinical impact, considerable technical challenges exist due to the inherent low signal‐to‐noise ratio. Purpose: To reduce scan time toward one breath‐hold by reconstructing diffusion tensors for in vivo cDTI with a fitting‐free deep learning approach. Study type: Retrospective. Population: A total of 197 healthy controls, 547 cardiac patients. Field strength/sequence: A 3 T, diffusion‐weighted stimulated echo acquisition mode single‐shot echo‐planar imaging sequence. Assessment: A U‐Net was trained to reconstruct the diffusion tensor elements of the reference results from reduced datasets that could be acquired in 5, 3 or 1 breath‐hold(s) (BH) per slice. Fractional anisotropy (FA), mean diffusivity (MD), helix angle (HA), and sheetlet angle (E2A) were calculated and compared to the same measures when using a conventional linear‐least‐square (LLS) tensor fit with the same reduced datasets. A conventional LLS tensor fit with all available data (12 ± 2.0 [mean ± sd] breath‐holds) was used as the reference baseline. Statistical tests: Wilcoxon signed rank/rank sum and Kruskal–Wallis tests. Statistical significance threshold was set at P = 0.05. Intersubject measures are quoted as median [interquartile range]. Results: For global mean or median results, both the LLS and U‐Net methods with reduced datasets present a bias for some of the results. For both LLS and U‐Net, there is a small but significant difference from the reference results except for LLS: MD 5BH (P = 0.38) and MD 3BH (P = 0.09). When considering direct pixel‐wise errors the U‐Net model outperformed significantly the LLS tensor fit for reduced datasets that can be acquired in three or just one breath‐hold for all parameters. Data conclusion: Diffusion tensor prediction with a trained U‐Net is a promising approach to minimize the number of breath‐holds needed in clinical cDTI studies. Evidence Level: 4 Technical Efficacy: Stage 1 [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10531807
Volume :
56
Issue :
6
Database :
Complementary Index
Journal :
Journal of Magnetic Resonance Imaging
Publication Type :
Academic Journal
Accession number :
160149705
Full Text :
https://doi.org/10.1002/jmri.28199