Back to Search
Start Over
Reliability Evaluation Based on Mathematical Degradation Model for Vacuum Packaged MEMS Sensor.
- Source :
- Micromachines; Oct2022, Vol. 13 Issue 10, p1713-N.PAG, 11p
- Publication Year :
- 2022
-
Abstract
- Vacuum packaging is used extensively in MEMS sensors for improving performance. However, the vacuum in the MEMS chamber gradually degenerates over time, which adversely affects the long-term performance of the MEMS sensor. A mathematical model for vacuum degradation is presented in this article for evaluating the degradation of vacuum packaged MEMS sensors, and a temperature-accelerated test of MEMS gyroscope with different vacuums is performed. A mathematical degradation model is developed to fit the parameters of the degradation of Q-factor over time at three different temperatures. The results indicate that the outgassing rate at 85 °C is the highest, which is 0.0531 cm<superscript>2</superscript>/s; the outgassing rate at 105 °C is the lowest, which is 0.0109 cm<superscript>2</superscript>/s; and the outgassing rate at 125 °C is in the middle, which is 0.0373 cm<superscript>2</superscript>/s. Due to the different mechanisms by which gas was released, the rate of degradation did not follow this rule. It will also be possible to predict the long-term reliability of vacuum packaged MEMS sensors at room temperature based on this model. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 2072666X
- Volume :
- 13
- Issue :
- 10
- Database :
- Complementary Index
- Journal :
- Micromachines
- Publication Type :
- Academic Journal
- Accession number :
- 159909121
- Full Text :
- https://doi.org/10.3390/mi13101713