A mathematical model to predict the different isodose volumes using TRAK value in HDR intracavitary brachytherapy for revised Manchester and ICRU-89 based Point A plans using computer tomography images.

Authors :
Mourya, Ankur
Choudhary, Sunil
Sharma, Neeraj
Shahi, Uday
Singh, Gaganpreet
Pradhan, Satyajit
Aggarwal, Lalit
Shahi, Uday Pratap
Aggarwal, Lalit Mohan
Source :
Journal of Cancer Research & Therapeutics; Jul-Sep2022, Vol. 18 Issue 4, p1105-1113, 9p
Publication Year :
2022

Abstract

<bold>Purpose: </bold>To find out the simple relationship between Total Reference Air Kerma (TRAK) and various isodose volumes. Calculated isodose volumes were compared with experimental data for revised Manchester and International Commission on Radiation Units and measurements (ICRU)-89 Point A-based treatment plans. The accuracy of the formula was compared with the results of other relationships available in the literature.<bold>Materials and Methods: </bold>Dosimetric data from 62 intracavitary brachytherapy (ICBT) treatment plans of 31 patients with cervical cancer were studied. Each patient had treatment plans normalized to revised Manchester and ICRU-89 Points A (Aflange and Aicru89). For each treatment plan, TRAK values, V350, V700, V1050, and V1400 were obtained. The modeling curve was plotted between Isodose volume (Vd) and the ratio of d/TRAK obtained from Aflange plans to get a mathematical relation. The results of this formula were compared with the experimental data and outcomes of other formulas available in the literature. A paired-sample t-test was performed to assess the statistical significance.<bold>Results: </bold>In the case of revised Manchester-based Aflange normalization plans, the mean isodose volume of V350, V700, V1050, and V1400 were 285.98 ± 32.3 cm3, 101.96 ± 10.63 cm3, 52.71 ± 4.72 cm3, and 31.44 ± 2.33 cm3 respectively. Likewise, for ICRU-89 based Aicru89 normalization plans, the mean isodose volumes of V350, V700, V1050, and V1400 were 304.11 ± 26.17 cm3, 108.88 ± 8.29 cm3, 56.62 ± 3.69 cm3 and 34 ± 2.23 cm3 respectively. The mean difference was significant. The Mathematical relationship developed was [INLINE:1]. No correlation was found between TRAK and D0.1cm3,D2cm3 for organs at risk.<bold>Conclusions: </bold>The developed formula calculated isodose volumes within the accuracy of ± 3% in ICBT plans. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09731482
Volume :
18
Issue :
4
Database :
Complementary Index
Journal :
Journal of Cancer Research & Therapeutics
Publication Type :
Academic Journal
Accession number :
159359494
Full Text :
https://doi.org/10.4103/jcrt.jcrt_47_21