Back to Search Start Over

Development of a Fully Automated Desktop Analyzer and Ultrahigh Sensitivity Digital Immunoassay for SARS-CoV-2 Nucleocapsid Antigen Detection.

Authors :
Chiba, Ryotaro
Miyakawa, Kei
Aoki, Kotaro
Morikawa, Takamitsu J.
Moriizumi, Yoshiki
Degawa, Takuma
Arai, Yoshiyuki
Segawa, Osamu
Tanaka, Kengo
Tajima, Hideji
Arai, Susumu
Yoshinaga, Hisatoshi
Tsukada, Ryohei
Tani, Akira
Fuji, Haruhito
Sato, Akinobu
Ishii, Yoshikazu
Tateda, Kazuhiro
Ryo, Akihide
Yoshimura, Toru
Source :
Biomedicines; Sep2022, Vol. 10 Issue 9, p2291-2291, 12p
Publication Year :
2022

Abstract

Background: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) outbreak has had a significant impact on public health and the global economy. Several diagnostic tools are available for the detection of infectious diseases, with reverse transcription-polymerase chain reaction (RT-PCR) testing specifically recommended for viral RNA detection. However, this diagnostic method is costly, complex, and time-consuming. Although it does not have sufficient sensitivity, antigen detection by an immunoassay is an inexpensive and simpler alternative to RT-PCR. Here, we developed an ultrahigh sensitivity digital immunoassay (d-IA) for detecting SARS-CoV-2 nucleocapsid (N) protein as antigens using a fully automated desktop analyzer based on a digital enzyme-linked immunosorbent assay. Methods: We developed a fully automated d-IA desktop analyzer and measured the viral N protein as an antigen in nasopharyngeal (NP) swabs from patients with coronavirus disease. We studied nasopharyngeal swabs of 159 and 88 patients who were RT-PCR-negative and RT-PCR-positive, respectively. Results: The limit of detection of SARS-CoV-2 d-IA was 0.0043 pg/mL of N protein. The cutoff value was 0.029 pg/mL, with a negative RT-PCR distribution. The sensitivity of RT-PCR-positive specimens was estimated to be 94.3% (83/88). The assay time was 28 min. Conclusions: Our d-IA system, which includes a novel fully automated desktop analyzer, enabled detection of the SARS-CoV-2 N-protein with a comparable sensitivity to RT-PCR within 30 min. Thus, d-IA shows potential for SARS-CoV-2 detection across multiple diagnostic centers including small clinics, hospitals, airport quarantines, and clinical laboratories. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
22279059
Volume :
10
Issue :
9
Database :
Complementary Index
Journal :
Biomedicines
Publication Type :
Academic Journal
Accession number :
159274787
Full Text :
https://doi.org/10.3390/biomedicines10092291