Back to Search
Start Over
A single-dose, randomized, open-labeled, parallel-group study comparing the pharmacokinetics, pharmacodynamics and safety of leuprolide acetate microspheres 3.75mg and Enantone® 3.75mg in healthy male subjects.
- Source :
- Frontiers in Pharmacology; 8/19/2022, Vol. 13, p1-10, 10p
- Publication Year :
- 2022
-
Abstract
- Leuprolide acetate microspheres developed by Shanghai Livzon Pharmaceutical Co., Ltd. (T) have been marketed in China for more than 10 years, benefiting a large number of patients, and will continue to play an important role in China. However, as a generic drug, it is unclear whether there is a difference in efficacy between T and the original product Enantone<superscript>®</superscript> (R). This study compared the differences in efficacy and safety of two 1-month depot formulations in 48 healthy Chinese male subjects by comparing multiple pharmacokinetic (PK) and pharmacodynamic (PD) parameters. The main research indicators were the PK parameters of leuprolide (C<subscript>max</subscript>, AUC<subscript>0-t</subscript>, AUC<subscript>0-D7</subscript>, and AUC<subscript>D7-t</subscript>) and the PD parameters of testosterone (E<subscript>max</subscript>, AUEC<subscript>0-t</subscript>, AUEC<subscript>0-D7</subscript>, and AUEC<subscript>D7-t</subscript>) after 42 days of administration. The C<subscript>max</subscript>, AUC<subscript>0-t</subscript>, AUC<subscript>0-D7</subscript> and AUC<subscript>D7-t</subscript> of leuprolide were slightly higher in the T group than in the R group with 90% confidence intervals (CIs) of 94.43–118.53%, 109.13–141.88%, 109.53–139.54%, and 105.17–145.74%, respectively. No significant differences in the PD parameters (E<subscript>max</subscript>, AUEC<subscript>0-t</subscript>, AUEC<subscript>0-D7</subscript>, and AUEC<subscript>D7-t</subscript>) existed between the T and R groups, and 90% CIs were 62.80–93.57%, 88.17–110.55, 95.72%–118.50%, and 79.77–105.63, respectively. At 672 h (D28), the castration rate of T was 91.30% (21/23) and that of R was 60.87% (14/23). The PK characteristics were consistent and the inhibitory effects on testosterone levels were similar in both T and R groups; further, clinical safety was observed for both T and R formulations, suggesting that these two products can replace each other in clinical practice. [ABSTRACT FROM AUTHOR]
- Subjects :
- LEUPROLIDE
PHARMACODYNAMICS
PHARMACOKINETICS
MICROSPHERES
ACETATES
Subjects
Details
- Language :
- English
- ISSN :
- 16639812
- Volume :
- 13
- Database :
- Complementary Index
- Journal :
- Frontiers in Pharmacology
- Publication Type :
- Academic Journal
- Accession number :
- 158918697
- Full Text :
- https://doi.org/10.3389/fphar.2022.946505