Back to Search Start Over

Reinforcement of mounting seams in constructive systems with without a crossbar framework. Part 2.

Authors :
Shcherbin, S. A.
Gorbach, P. S.
Glotov, A. A.
Glotov, V. A.
Source :
AIP Conference Proceedings; 2022, Vol. 2434 Issue 1, p1-5, 5p
Publication Year :
2022

Abstract

The second part of the article describes the work on strengthening the joints between the prefabricated slabs of the constructive systems with without a crossbar framework by gluing fiberglass and on static testing of the reinforced node. According to the results of the tests, a conclusion was made about the effectiveness and expediency of using the chosen reinforcement method to increase the strength and rigidity of the beam-free floor. [ABSTRACT FROM AUTHOR]