Bone versus soft-tissue setup in proton therapy for patients with oesophageal cancer.
- Source :
- Acta Oncologica; Aug2022, Vol. 61 Issue 8, p994-1003, 10p, 2 Color Photographs, 3 Graphs
- Publication Year :
- 2022
-
Abstract
- The aim of this study was to investigate the effect of patient positioning based on either bone or soft-tissue matching for PT in oesophageal cancer and its impact on plan adaptation. Two retrospective patient cohorts treated with radiotherapy were included in the study. Cohort A consisted of 26 consecutive patients with a planning 4DCT scan (CT1) and a surveillance 4DCT scan (CT2) at fraction ten. Cohort B consisted of 17 patients selected based on large anatomical changes identified during treatment resulting in a rescan (CT2). Mean dose to the iCTV (sum of the CTVs in all respiratory phases) was 50.4 Gy (RBE) in 28 fractions or 41.4 Gy (RBE) in 23 fractions. A nominal pencil beam scanning plan was created using two posterior beams and robust optimization (5 mm setup, 3.5% range). For each patient, two rigid registrations were made between average (avg) CT1 and CT2: a match on the vertebral column (bone match) and a match on the iCTV (soft-tissue match). Robustness towards setup (5 mm) and range (3.5%) errors was evaluated at CT2. Robustness towards respiration was evaluated by recalculation of the plan on all phases of the CT2 scan. Dose coverage <96% would trigger adaptation. The statistical significance (p-value <0.05) between dose coverage for the two registration methods was assessed using the Wilcoxon signed rank test. All plans fulfilled V95%<subscript>iCTV</subscript>>99% for the nominal plan and V95%<subscript>iCTV</subscript>>97% for all respiratory phases and robustness scenarios at CT1. In two (8%) and three (18%) patients, V95%<subscript>iCTV</subscript><96% on CT2 for Cohort A and B, respectively when bone match was used. For soft-tissue match, V95%iCTV >96% for all patients. V95%<subscript>iCTV</subscript> was significantly higher (p-value = 0.0001) for soft-tissue match than bone match. Anatomical changes during the treatment course led to target dose deterioration and a need for plan adaptation when using a bone match. [ABSTRACT FROM AUTHOR]
- Subjects :
- PUBLIC health surveillance
STATISTICS
DIGITAL image processing
COMPUTER software
BONES
PATIENT selection
RESEARCH methodology
RETROSPECTIVE studies
CANCER patients
SOFT tissue tumors
PROTON therapy
RADIATION doses
RADIOTHERAPY
DATA analysis
COMPUTED tomography
ESOPHAGEAL tumors
PATIENT positioning
LONGITUDINAL method
RECORDING & registration
Subjects
Details
- Language :
- English
- ISSN :
- 0284186X
- Volume :
- 61
- Issue :
- 8
- Database :
- Complementary Index
- Journal :
- Acta Oncologica
- Publication Type :
- Academic Journal
- Accession number :
- 158571796
- Full Text :
- https://doi.org/10.1080/0284186X.2022.2091949