Back to Search Start Over

Graded lower body negative pressure induces intraventricular negative pressures and incremental diastolic suction: a pressure-volume study in a porcine model.

Authors :
Berboth, Leonhard
Zirngast, Birgit
Manninger, Martin
Steendijk, Paul
Tschöpe, Carsten
Scherr, Daniel
Hinghofer-Szalkay, Helmut G.
Goswami, Nandu
Petersen, Lonnie G.
Mächler, Heinrich
Alogna, Alessio
Source :
Journal of Applied Physiology; Jul2022, Vol. 133 Issue 1, p20-26, 7p
Publication Year :
2022

Abstract

Lower body negative pressure (LBNP) is a tool to study compensatory mechanisms to central hypovolemia for decades. However, the underlying hemodynamic mechanisms were mostly assessed noninvasively and remain unclear. We hypothesized that incremental LBNP reduces diastolic filling and thereby affects left ventricular (LV) diastolic suction (DS). Here, we investigated the impact of graded LBNP at three different levels of seal as well as during b-adrenergic stimulation by invasive pressure- volume (PV) analysis. Eight Landrace pigs were instrumented closed-chest for PV assessment. LBNP was applied at three consecutive locations: I) cranial, 10 cm below xiphoid process; II) medial, half-way between cranial and caudal; III) caudal, at the iliac spine. Level III was repeated under dobutamine infusion. At each level, baseline measurements were followed by application of incremental LBNP of -15, -30, and -45 mmHg. LBNP induced varying degrees of preload-dependent hemodynamic changes, with cranial LBNP inducing more pronounced effects than caudal. According to the Frank–Starling mechanism, graded LBNP progressively reduced LV stroke volume (LV SV) following a decrease in LV end-diastolic volume. Negative intraventricular minimal pressures were observed during dobutamine-infusion as well as higher levels of LBNP. Of note, incremental LV negative pressures were accompanied by increasing DS volumes, derived by extrapolating the volume at zero transmural pressure, the so-called equilibrium volume (V0), related to LV SV. In conclusion, graded preload reduction via LBNP shifts the PV loop to smaller volumes and end-systolic volume below V0, which induces negative LV pressures and increases LV suction. Accordingly, LBNP-induced central hypovolemia is associated with increased DS. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
87507587
Volume :
133
Issue :
1
Database :
Complementary Index
Journal :
Journal of Applied Physiology
Publication Type :
Academic Journal
Accession number :
158273438
Full Text :
https://doi.org/10.1152/japplphysiol.00110.2022