This paper proposes a new approach to above- $f_{max}$ power detection, using harmonic injection locking of a cross-coupled oscillator and the resulting change in oscillation amplitude. The paper starts with the development of a theoretical framework for this receiver. Two previous methodologies are combined: analyzing an injection-locked oscillator as an active device in a positive feedback loop with a frequency selective network; and the more recently proposed way of modeling non-linearities by using inter-harmonic translation coefficients. Using this framework, a compact equation for the expected voltage response of the receiver is derived. Finally, the design of a receiver consisting of a 200 GHz cross-coupled oscillator with a 600 GHz folded dipole antenna as its tank inductor is discussed. A Noise Equivalent Power (NEP) of 2.3 pW/ $\sqrt {\text {Hz}}$ is achieved with the proposed receiver. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15498328
Volume :
69
Issue :
8
Database :
Complementary Index
Journal :
IEEE Transactions on Circuits & Systems. Part I: Regular Papers
Publication Type :
Periodical
Accession number :
158241944
Full Text :
https://doi.org/10.1109/TCSI.2022.3174402