Back to Search
Start Over
RRU 5G 8T8R Heatsink Embedded Vapor Chamber and Heat Pipe Assemblies.
- Source :
- Proceedings of the International Conference on Industrial Engineering & Operations Management; 11/3/2021, p1368-1373, 6p
- Publication Year :
- 2021
-
Abstract
- Remote Radio Unit-RRU 5G Heatsink systems are using natural convection cooling due to some outstanding advantages such as low cost, high reliability, noiseless operation, and hard environment operation. However, some main disadvantages such as a relatively low heat transfer and low heat dissipation density are to be solved by optimal heat sink fin design. This paper describes an optimal heatsink fin profile design with V shape angle to maximize natural cooling for RRU 5G embedded heat pipe and vapor chamber technology. Several core ICs of RRU 5G with high heat loss sources up to a hundred W are embedded copper plates and heat pipes. Temperature measurements were carried out to validate the RRU 5G 8T8R heatsink modeling and experimental methods. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 21698767
- Database :
- Complementary Index
- Journal :
- Proceedings of the International Conference on Industrial Engineering & Operations Management
- Publication Type :
- Conference
- Accession number :
- 156792924