Back to Search
Start Over
The study of temperature measurement based on the transmission of fixed wavelengths for helical long-period grating.
- Source :
- Optica Applicata; 2022, Vol. 52 Issue 1, p129-137, 9p
- Publication Year :
- 2022
-
Abstract
- This research involves a fixed wavelength and dual-wavelength ratio temperature measurement for helical long-period grating. There are two resonant dips near 1475 and 1520 nm, with the pitch length 782 μm. The temperature sensitivity of resonance wavelengths is about 0.06 nm/°C. Both theoretical simulation and experiment results show that the transmission of a fixed wavelength lin- early changes with the temperature. It has a high application value for measuring temperature. Be- sides, the dual-wavelength ratio is studied to eliminate the influence of light source. The temperature sensitivity of transmission intensity ratio of I1469.6nm/I0 and I1469.6nm/I1526.5nm are about 1.0076/°C and 0.0155/°C, respectively, so the dual-wavelength ratio is more practical. And the 0.0155 times intensity change could be much more easily measured than the 0.06 nm wavelength change for each degree Celsius. So the dual-wavelength ratio of the helical long-period gratings is very suitable for temperature sensors. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00785466
- Volume :
- 52
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- Optica Applicata
- Publication Type :
- Academic Journal
- Accession number :
- 156366363
- Full Text :
- https://doi.org/10.37190/oa220110