Back to Search Start Over

The long‐term outcomes of cardiac implantable electronic devices implanted via the femoral route.

Authors :
Griffiths, Samuel
Behar, Jonathan M.
Kramer, Daniel B.
Debney, Mike T.
Monkhouse, Christopher
Lefas, Alicia Y.
Lowe, Martin
Amin, Fouad
Cantor, Emily
Boyalla, Vennela
Karim, Nabeela
Till, Jan
Markides, Vias
Clague, Jonathan R.
Wong, Tom
Source :
Pacing & Clinical Electrophysiology; Apr2022, Vol. 45 Issue 4, p481-490, 10p
Publication Year :
2022

Abstract

Background: Conventional superior access for cardiac implantable electronic devices (CIEDs) is not always possible and femoral CIEDs (F‐CIED) are an alternative option when leadless systems are not suitable. The long‐term outcomes and extraction experiences with F‐CIEDs, in particular complex F‐CIED (ICD/CRT devices), remain poorly understood. Methods: Patients referred for F‐CIEDs implantation between 2002 and 2019 at two tertiary centers were included. Early complications were defined as ≤30 days following implant and late complications >30 days. Results: Thirty‐one patients (66% male; age 56 ± 20 years; 35% [11] patients with congenital heart disease) were implanted with F‐CIEDs (10 ICD/CRT and 21 pacemakers). Early complications were observed in 6.5% of patients: two lead displacements. Late complications at 6.8 ± 4.4 years occurred in 29.0% of patients. This was higher with complex F‐CIED compared to simple F‐CIED (60.0% vs. 14.3%, p =.02). Late complications were predominantly generator site related (n = 8, 25.8%) including seven infections/erosions and one generator migration. Eight femoral generators and 14 leads (median duration in situ seven [range 6–11] years) were extracted without complication. Conclusions: Procedural success with F‐CIEDs is high with clinically acceptable early complication rates. There is a notable risk of late complications, particularly involving the generator site of complex devices following repeat femoral procedures. Extraction of chronic F‐CIED in experienced centers is feasible and safe. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01478389
Volume :
45
Issue :
4
Database :
Complementary Index
Journal :
Pacing & Clinical Electrophysiology
Publication Type :
Academic Journal
Accession number :
156130962
Full Text :
https://doi.org/10.1111/pace.14449