Back to Search Start Over

Operating performance of multi‐modular water‐phase change material tanks for emergency cooling in an underground shelter.

Authors :
Zeng, Chao
Yuan, Yanping
Cao, Xiaoling
Dardir, Mohamed
Panchabikesan, Karthik
Ji, Wenhui
Leng, Ziyu
Source :
International Journal of Energy Research; 3/25/2022, Vol. 46 Issue 4, p4609-4629, 21p
Publication Year :
2022

Abstract

Summary: Latent heat thermal energy storage can not only alleviate the mismatch between supply and demand but also improve the performance and dependability of the energy system. Unfortunately, previous research achieves a specific engineering load shifting using a single water‐phase change material (PCM) tank, the volume of which is tailored to the specific cooling or heating load. This paper proposes the concept of multi‐modular water‐PCM tanks (MMWPT), which offer flexibility and are simple to be mass‐produced, as thermal storage in an underground shelter's emergency mode. The thermal inertia of the geothermal energy is used to remain the PCM at solid state at first and to naturally cool the tank once they are melted. The mathematical model is created in MATLAB and validated by experiment with an NMBE of less than ±10% and RMSE of less than 30%. In addition, the MMWPT's thermal performance in various matrixes was investigated in an underground shelter where the peak load occurs suddenly and with low frequency. The result reveals that the ∆Twater in the scenario with matrix form of N (number of tanks in series) × 5 (number of tanks in parallel) is almost four times as that with matrix form of N × 1. By separating the water into five parallel water tanks, the corresponding EDD is 1.27‐1.28 times larger. Changing the N from 1 to 2 and 3 could increase the EDD by 3.0%‐12.5% and 5.9%‐25%, respectively. Three acceptable MMWPT matrixes were presented using the effective discharging duration (EDD) and temperature drop as assessment criteria. Additionally, PCM with a maximum phase change temperature (Tpch_PCM) of 19.41°C and a connection matrix of 3 × 4 is recommended when using a single charging cycle or active cooling approach. Otherwise, a Tpch_PCM of 22.41°C with a connection matrix of 3 × 5 is advised. This research is planned to give references for using the MMWPT in underground shelters to shift loads. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0363907X
Volume :
46
Issue :
4
Database :
Complementary Index
Journal :
International Journal of Energy Research
Publication Type :
Academic Journal
Accession number :
155808773
Full Text :
https://doi.org/10.1002/er.7454