Back to Search Start Over

TIP, TORQUE & ROTATIONS: How accurately do digital superimposition software packages quantify tooth movement?

Authors :
Adel, Samar M.
Vaid, Nikhilesh R.
El-Harouni, Nadia
Kassem, Hassan
Zaher, Abbas R.
Source :
Progress in Orthodontics (2196-1042); 3/14/2022, Vol. 23 Issue 1, p1-10, 10p
Publication Year :
2022

Abstract

Background: To investigate the accuracy of three different 3D digital model registration software for tip, torque and rotation measurements, with reference to a 3D digital virtual setup. Twenty maxillary and mandibular pre-treatment scans of patients undergoing clear aligner therapy were used. Digital setups were generated from pre-treatment scans using a tooth movement software. Both the pretreatment digital scans (T1) and digital setups (T2) were converted to STL files to be exported to the 3 studied software that employed: (1) Semiautomatic best fit registration (S-BF), (2) Interactive surface-based registration (I-SB), and (3) Automatic best fit registration (A-BF) respectively. Changes in tip, torque and rotation were calculated for all the registered pairs. Results: The change in tooth position was compared between the calculated tooth movement using each of the registration software packages versus the actual generated tooth movement from the digital setups. Continuous data was expressed as mean and standard deviation. Intra Class Correlation Coefficient for agreement between digital simulation and each software was used. Intra and Inter-examiner reliabilities were also assessed using Intra Class Correlation Coefficient. Significance of the obtained results was expressed at p ≤ 0.01. Semiautomatic best fit registration software showed excellent agreement (> 0.90) for all tooth movements, except for good agreement for torque (0.808). Interactive surface-based registration software showed moderate agreement for all measurements (0.50 and < 0.75), except for good agreement for rotation (0.783). Automatic best fit registration software demonstrated excellent agreement (> 0.90) for rotation, good agreement for tip (0.890) and moderate agreement for torque (0.740). Conclusions: Overall, semiautomatic best fit registration software consistently showed excellent agreement in superimpositions compared to other software types. Automatic best fit registration software consistently demonstrated better agreement for mandibular superimpositions, compared to others. Accuracy of digital model superimpositions for tooth movements studied in superimposition studies, can be attributed to the algorithm employed for quantification. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
21961042
Volume :
23
Issue :
1
Database :
Complementary Index
Journal :
Progress in Orthodontics (2196-1042)
Publication Type :
Academic Journal
Accession number :
155757328
Full Text :
https://doi.org/10.1186/s40510-022-00402-x