Back to Search
Start Over
Reloadable Stapler Use during Peripartum Hysterectomy for Placenta Accreta Spectrum: A Novel Surgical Technique and Case Series.
- Source :
- American Journal of Perinatology; Feb2022, Vol. 39 Issue 3, p265-271, 7p
- Publication Year :
- 2022
-
Abstract
- Objective This study aimed to describe a novel surgical technique for the management of antenatally suspected placenta accreta spectrum (PAS). Study Design This is a retrospective, case series of patients with suspected PAS undergoing peripartum hysterectomy with a reloadable articulating stapler at a tertiary care center. Results Eighteen patients with antenatally suspected PAS were identified and underwent peripartum hysterectomy with the aid of a reloadable stapler. Mean gestational age at delivery was 34 <superscript>4/7</superscript> ± 1 <superscript>1/7</superscript> weeks. Mean total operative time (skin-to-skin) was 117.3 ± 39.3 minutes, and 79.8 ± 19.8 minutes for the hysterectomy. Mean blood loss for the entire case was 1,809 ± 868 mL. Mean blood loss for the hysterectomy was 431 ± 421 mL. Mean units of intraoperative red blood cells transfused was 3 ± 1 units. Mean units of postoperative red blood cells transfused was 1 ± 0.5 units. Five cases were complicated by urological injury (two intentional cystotomies). Four patients were admitted to the intensive care unit (ICU) for a mean of ≤24 hours. Mean postoperative LOS was 4.11 ± 1.45 days. Three patients had final pathology that did not demonstrate PAS while four were consistent with accreta, six increta, and five percreta. Conclusion Use of a reloadable articulating stapler device as part of the surgical management of antenatally suspected PAS results in a shorter operative time (117 ± 39 minutes vs. 140–254 minutes previously reported), lower average blood loss (1,809 ± 868 mL vs. 2,500–5,000 mL previously reported) and shorter LOS (4.11 ± 1.45 days vs. 9.8 ± 13.5 days previously reported) compared with traditional cesarean hysterectomy. The reloadable stapling device offers an advantage of more rapidly achieving hemostasis in the surgical management of PAS. Key Points PAS is associated with severe maternal morbidity. Decreased operative time and blood loss have many clinical benefits. Reloadable stapler use for PAS decreases operative time. Reloadable stapler use for PAS decreases operative blood loss. [ABSTRACT FROM AUTHOR]
- Subjects :
- SUTURING
SURGICAL blood loss
LENGTH of stay in hospitals
HYSTERECTOMY
CONFIDENCE intervals
RETROSPECTIVE studies
GESTATIONAL age
SURGICAL complications
SURGERY
PATIENTS
HEMOSTASIS
PLACENTA accreta
CASE studies
DESCRIPTIVE statistics
STAPLERS (Surgery)
ODDS ratio
PERINATAL period
HEMORRHAGE
LONGITUDINAL method
Subjects
Details
- Language :
- English
- ISSN :
- 07351631
- Volume :
- 39
- Issue :
- 3
- Database :
- Complementary Index
- Journal :
- American Journal of Perinatology
- Publication Type :
- Academic Journal
- Accession number :
- 155179055
- Full Text :
- https://doi.org/10.1055/s-0040-1715464